Auditor
11
Voltage
The rear panel voltage selector switch serves to let the user switch to
the local line voltage standard.
IMPORTANT ADVICE: Before you use the Auditor, make sure
that this switch setting reflects the correct local power
line voltage (115 V position: 110-120 volts/6o Hz, 230 V
position: 220-240 volts/50 Hz).
Power Connection and Fuse
Connect the included power cord to the rear power supply socket.
Transformer, power cord and case connection conform to VDE, UL
and CSA requirements. The power fuse is installed behind the clack
right to the power connector. Power fuse ratings are 200 mA slow blow
(220-240 volts) or 400 m A slow blow (110-120 volts).
On/Off Switch
The rear panel On/Off switch activates the unit, confirmed by the light-
ed POWER LED on the front panel.
IMPORTANT ADVICE: Switch on the unit only after you have turned the
Volume control fully left, and wait to set your desired volume level
until the unit is powered on. Neglecting this can damage either or both
your ears and your headphones!
Rear Panel/Connections
Sockets & Switches