Power Connection

Connect the included power cord to the rear Mains Input. Transformer, 
power cord and case connection conform to VDE, UL and CSA require-
ments.  Power  fuse  ratings  are  315 mA  slow  blow  (220-240  volts)  or 
630 mA slow blow (110-120 volts). 

Power Switch

The  rear  panel  POWER  switch  activates  the  unit,  confirmed  by  the 
Power LED on the front panel (between the headphone symbols). 

IMPORTANT ADVICE: Switch on the unit only after you have 
turned all VOLUME controls fully left, and wait to set your 
desired volume level until the unit is powered on. Neglecting 

this can damage either or both your ears and your headphones!

GND LIFT Switch

The rear panel GND LIFT switch eliminates hum by separating the in-
ternal ground from the unit’s housing ground. Hum can, for example, 
result when this unit’s housing has a common ground connection with 
other machines that might have a different ground potential. 

Input Sensitivity IN 2

Inputs IN 1 and IN 2 are gauged to analog line level signals at +4 dBu. 
The second input IN 2 can alternatively be set to another input sensi-
tivity of -10dBV nominal level with the switch next to the IN2 inputs. A 
nominal level of +4 dBu represents the international standard of pro-
fessional  studio  equipment,  -10dBV  corresponds  to  the  standard  in 
consumer electronics, for example a CD/DVD-Player for home use. 

If the switch is actuated, IN 2 is set to +4 dBu, if the switch is not actu-
ated, sensitivity of IN 2 is set to -10 dBV. If you connect a unit adjusted to 
-10dBV to a +4 dBu input, the signal is too quiet (and too loud vice versa). 
In this case change the switch position accordingly.

Rear Panel/Switches & Connections

Содержание 2Control 2860

Страница 1: ...ontroller 2860 Control ON VOLUME 1 2 POWER 8 0 4 7 3 6 3 0 2 5 2 2 1 9 1 6 12 10 8 6 4 5 3 1 0 1 3 4 5 5 5 6 5 7 CROSSFEED 0 1 2 3 4 5 6 7 8 9 1 0 VOLUME VOLUME IN 1 IN 2 MONO DIM SP 1 SP 2 SP 3 Made...

Страница 2: ...ectronics GmbH Type of Equipment Audio Signal Processor Product 2Control Model 2860 Test Basis EN50081 1 1992 EN50082 1 1992 EN60065 1993 EN61000 3 3 1995 EN60065 2002 EN55013 2001 EN55020 2002 EN6100...

Страница 3: ...1 Wiring 11 Rear Panel Switches Connections 12 Voltage Selector 12 Power Connection Power Switch GND Lift Switch Input Sensitivity IN 2 13 XLR Sockets Unbalanced Connections e g RCA 14 Front Panel Con...

Страница 4: ...E YOU AWARE OF IMPORTANT OPERATIONAL ADVICE AND OR WARNINGS THAT MUST BE FOLLOWED BE ESPECIALLY ATTENTIVE TO THESE AND ALWAYS FOLLOW THE ADVICE THEY GIVE The symbol of a lamp directs your attention to...

Страница 5: ...s electrical shock Electrical power Run this machine ONLY from sources which can provide proper power at the prescribed rating When in doubt about a source contact your dealer or a professional electr...

Страница 6: ...sign of hav ing been damaged This also applies to any situation in which the unit has not been subjected to any of these unusual circumstances but still is not functioning normally or its performance...

Страница 7: ...ainst HF interference Nonetheless you should carefully consider where you place the unit to avoid electrical disturbances It should be positioned so that you can easily reach it but there are other co...

Страница 8: ...ol s active designs do not influence impedances when levels change Altering impedances would again have effects on the frequency response so the 2Control s active design guarantees linearity Often the...

Страница 9: ...ics Speakers or headphones The 2Control encompasses advantages of both kinds of monitoring methods On one hand the analytical headphone monitoring is like working with an acoustic magnifier but withou...

Страница 10: ...der control and can rely on first class quality Extend the range of headphone applications At home nocturnal engineers now have an alternative to full range monitors for judging stereo imaging in thei...

Страница 11: ...GERMANY AVIS RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR WARNING DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE THIS EQUIPMENT MUST BE EARTHED RISK OF ELECTRIC SHOCK D O N O T O P E N C AUTION L R R L L R SP...

Страница 12: ...1 GND Pin 2 hot Pin 3 cold Connect Pin 3 to GND for unbal operation SP 3 Full Range Mono Output To Sub or Mono Speaker L R R IN 2 IN 2 L 4 dBu 10 dBV 230 SP 3 VOLTAGE FUSE Electrical Power Power Swit...

Страница 13: ...ground from the unit s housing ground Hum can for example result when this unit s housing has a common ground connection with other machines that might have a different ground potential Input Sensitiv...

Страница 14: ...ablish unbalanced connections easily and without adaptors for example from CD Players with RCA outputs or to HiFi power am plifiers with RCA inputs It is important to pay attention to the correct pola...

Страница 15: ...volume setting of a first headphone at a much higher even painful level Warning NEVER plug in a mono 1 4 jack TS to the headphone output The use of a mono 1 4 will lead to a short circuit that will de...

Страница 16: ...dB Normally you employ this function when mixing to choose between two defined volumes to avoid having to move the VOLUME control Volume Control Speakers The VOLUME level control allows you to increas...

Страница 17: ...ugh one channel and loud speaker at a time A recommendable calibration is the playback of a 83dB SPL reference signal at the playback location a common refer encevolumelevel TheDAWoutputlevelshouldbea...

Страница 18: ...coherent conditions in speaker and headphone monitoring The circuitry for the CROSSFEED control is derived from the reference headphone amplifier Phonitor In the Phonitor the loudspeaker imag ing sim...

Страница 19: ...olerances at the start of the control range but it also would reduce the overall am plification which may be needed when listening to low level signals in a mix Use the control range above scale posit...

Страница 20: ...uency range 10Hz to 100kHz 3dB CMRR 60dB 1kHz 0dBu input level unity gain THD N 0 002 1kHz 0dBu input level unity gain Signal to noise ratio 96dB Headphones 85dB A weighted Crosstalk L R 70dB 1kHz Dyn...

Страница 21: ...2Control 21 Block Diagram...

Страница 22: ...O L U M E 1 2 P O W E R 8 0 4 7 3 6 3 0 2 5 2 2 1 9 1 6 1 2 1 0 8 6 4 5 3 1 0 1 3 4 5 5 5 6 5 7 C R O S S F E E D 0 1 2 3 4 5 6 7 8 9 1 0 V O L U M E V O L U M E IN 1 IN 2 MONO DIM SP 1 SP 2 SP 3 Made...

Страница 23: ...through their distribu tor or dealer In such cases please contact your dealer for full guaran tee conditions and service Direct SPL product support requires product registration Please fill out the g...

Страница 24: ...Model 2860 Manual 2Control spl info...

Отзывы: