SPL-Laboratory Smart Voltmeter 2014 Скачать руководство пользователя страница 4

 

with sag and swell indication mode the car voltmeter displays current voltage and in case if the 

permitted range is overstepped, the voltmeter will inform the user about it by holding maximum 

or minimum value onscreen for evaluating the degree of sag or swell. In the protection mode in 

case if the permitted range is overstepped, the voltmeter will break the remote controlling circuit 

before user’s interference, protecting electrical equipment from breakage in doing so. It stands to 

mention that Smart Voltmeter is able to commutate the Remote controlling circuit with current 

up to 3 ampere, thus in case of necessity replacing an additional relay.Smart Monitor form Spl-

Lab will protect your car audio components from breakage, will help in tuning sound in the car, 

as well as will measure power of  your sound system and acoustics characteristics. Actually the 

Smart  Monitor  replaces  amp  clamp,  True  RMS  digital  voltmeter,  and  oscilloscope,  and  in 

addition to this provides protecting functions.

 

Ergonomics

 

Spl-Lab  car  voltmeter  has  compact  case,  including  a  three-segment  display,  4  control  buttons, 

three-coloured  LED  for  indicating  active  working  mode  and  a  slot  for  five  contacts  that  has 

several variants of connection to the electric system of the car. The design of the device allows 

including it practically in any car interior. 

 

 

Содержание Smart Voltmeter 2014

Страница 1: ...Smart Voltmeter User Manual Multifunctional Digital Car Voltmeter with Protection Feature 2014 SPL Laboratory 01 01 2014...

Страница 2: ...dentifying the functional parts of the device 7 Number of the element 7 Description 7 Functional purpose of slot contacts 7 Number of the element 7 Description 7 Typical device connection schemes 8 Co...

Страница 3: ...wing measuring exact characteristics of a car electric network voltage analysing voltage sags and swells that appear in car electronics operation process protection of electrical equipment of a car fr...

Страница 4: ...t with current up to 3 ampere thus in case of necessity replacing an additional relay Smart Monitor form Spl Lab will protect your car audio components from breakage will help in tuning sound in the c...

Страница 5: ...uracy 0 1 Volt Data refresh speed one second half second quarter second Commutated current of the Remote circuit 3 ampere Algorithm of measuring direct voltage Averaging by time Display Three segment...

Страница 6: ...sult in its breakage To avoid the risk of electric shock all the connector cables should not have insulation defects Avoid measuring load beyond the maximum limit All operations of connecting and disc...

Страница 7: ...1 Negative common should be connected to the negative contact of the car electric network 2 12 V for feeding the device it is possible to connect to any supply line for example to the ignition or to...

Страница 8: ...3 Not connected 4 Not connected 5 Should be connected to the measured network spot Voltmeter with protection feature without external control This voltmeter connection scheme provides the use of exter...

Страница 9: ...ional button 4 Resetting current values and restoring the remote circuit or increasing the selected value in the configuration menu Setup mode For entering the configuration menu press Functional butt...

Страница 10: ...e on screen only in case if value overstepped the permissible range even more in so doing the LED and display start blinking until reset button is pressed The Remote controlling circuit is closed if t...