13. ASSEMBLY OF HIGH PRESSURE HOSE WITH THE UNIT 

  Connect the quick release high pressure hose to the outlet connector of the unit. 

 

 

 

 

 

 

 

 

 

 

 

14. WATER INLET CONNECTION 

  Connection to potable water mains can be achieved by fitting a general garden hose (3/4 inch 

diameter) and a hose clamp. 

  Connect the water supply hose to the water inlet connection. In case of poor water quality the use of an 

external water filter is recommended. Contact your Spitwater agent for advice and /or supply. 

  Make sure the water supply temperature and pressure meet the values specified in the technical data, 

then turn the water supply on. Visually check for leaks and contact your Spitwater service agent if 
found. 

  Open the water supply and fill the water tank. The float valve will automatically stop the water flow 

when the water tank is full. 

  Water that has flowed through backflow preventer is considered to be non-potable (non-drinkable). 

  For suction supply / non-pressure water supply, other than potable water mains, contact your 

authorized Spitwater service agent for advice. 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

WARNING:   

 

This high pressure cleaner is only 
allowed to be connected with the 
drinking water mains, when an 
appropriate backflow preventer has 
been installed, as per AS/NZS 
60335.2.79.  

 

Follow all local standards and 
regulations applicable to water 
connection. 

 

 

High pressure hoses, fittings and 
couplings are important for the 
safety of the machine. Use only 
high pressure hoses, couplings 
and fittings recommended by 
Spitwater. 

Do not pull on high pressure hose 
in order to move the unit. 

 

 

 

 

Содержание HP18160E GT

Страница 1: ...this instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufacturer fr...

Страница 2: ...accordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the m...

Страница 3: ...7 5 HP PUMP MODEL HTS6311 HT4718 OIL TYPE 15W 40 15W 40 OIL CAPACITY 0 36 1 1 L OTHER DETERGENT BOTTLE CAPACITY L VALUES DETERMINED AS PER AS NZS 60335 2 79 SOUND PRESSURE LEVEL Lp 75 78 4 dB A UNCER...

Страница 4: ...t cautious Their meaning is listed next to them for your attention CAUTION Electric shock hazard Disconnect power before removing cover DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUT...

Страница 5: ...ON OFF SWITCH HIGH PRESSURE HOSE PRESSURE LOW HIGH PLUG SCW83 G ONLY DUAL LANCE CHEMICAL SUCTION HOSE HIGH PRESSURE WATER OUTLET CONNECTOR Always pay attention to the safety instructions provided on...

Страница 6: ...ent PPE 2 ELECTRICAL CONNECTION The voltage hertz rating and number of phases on the serial label must correspond to that of the electrical mains outlet Only connect the unit to electrical installatio...

Страница 7: ...unit s power cord 6 TRIP HAZARD Loose extension cords and power cables provide a potential trip hazard especially when they cross pathways Take safety measures like placing traffic cones along the co...

Страница 8: ...er is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries o...

Страница 9: ...amage to the unit Spitwater recommends the use of original accessories and spare parts available through Spitwater and its extensive dealer network Never use a nozzle size other than that specified in...

Страница 10: ...t it from sliding or falling 4 If transporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or below 0 C contact you...

Страница 11: ...ed on the data plate and in the technical data in this manual This unit must be earthed Please note that incorrect voltage or insufficient power supply will cause immediate damage to the unit Note Any...

Страница 12: ...do not interchange during assembly Add nozzle shield after nozzle assembly Refer diagram below 12 LANCE TRIGGER GUN HIGH PRESSURE HOSE ASSEMBLY Connect the lance to the spray gun by an in built quick...

Страница 13: ...vice agent if found Open the water supply and fill the water tank The float valve will automatically stop the water flow when the water tank is full Water that has flowed through backflow preventer is...

Страница 14: ...he spray gun a few times to expel Note If this is the first use of the unit or the unit has been left idle for an extended period of time it is advisable to run this operation with the front part of t...

Страница 15: ...acid or corrosive products contact an authorized service agent or the manufacturer if in doubt 2 If detergent is required it CAN BE USED IN LOW PRESSURE ONLY To activate low pressure turn the lance h...

Страница 16: ...d water pressure in the unit by pulling the trigger of the spray gun then engage the spray gun trigger lock Failure to follow this instruction will leave the unit in a potentially unsafe manner 5 If t...

Страница 17: ...ents that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly serviced by an authorized Spitwater servi...

Страница 18: ...r units subjected to normal operating conditions Should the unit be subjected to abnormal conditions e g heavy use dirty water extreme temperatures or conditions etc times should be reduced accordingl...

Страница 19: ...appearance Check for any service due based on USAGE VS SERVICE FREQUENCY Table A Check pressure gauge to show working pressure as per Technical data sheet when the trigger is in ON position Check for...

Страница 20: ...unit is on a flat surface Check the oil level in the pump using the dipstick or the sight glass on the back side of the pump Make sure the level is between min max level notches on the dipstick or is...

Страница 21: ...w water cut off is activated Check that water diesel tank are full and add water diesel as necessary No power supply Contact an authorized electrician to check power supply When switch is activated th...

Отзывы: