background image

1

IM-P054-07  CH Issue 1

Spirax-Monnier MP Miniature Compressed Air Filter/Regulator

IM-P054-07

CH Issue 1

0544756/1

Printed in the UK

       © Copyright 1995

How to fit

Fit in a horizontal pipework, with the bowl ver-
tically downwards, as close as possible to the
equipment it is serving. Connect unit so that air
flow is in the direction shown by the arrow cast
on the body. A pressure gauge fitted to one of
the ports is recommended (to show the second-
ary pressure). The port(s) not in use should be
blanked off with the plugs supplied.
Panel Mounting: The panel must not exceed
8mm thick. The required hole is 31mm.

To adjust

Lift locking ring (2). Turn adjustment knob
(1) clockwise to increase pressure. Depress
locking ring to lock.
It is recommended that all adjustments are
made under flow conditions. There will be a
slight increase in set pressure when flow stops.

How does it work

The filter portion of the Spirax-Monnier MP2
combines the advantages of a centrifugal sepa-
rator and a fine mesh filter element. Contami-
nated compressed air (3) is directed to the
inside of the bowl (5) by the multi bladed whirl
disc (4). The preliminary separation allows most
of the liquids and the larger solid particles to
pass down into the sump (6) away from any
turbulence. The air is then filtered by a 5 micron
element (7) before flowing past the main valve
(8) of the regulator portion of the MP2. With the
adjustment knob (1) rotated fully anticlockwise,
the valve return spring (13) will keep the main
valve (8) shut. Clockwise rotation of the adjust-
ment knob will compress the main control spring
(11), deflect the diaphragm assembly down-
wards (10), opening the main valve (8). As air
flows to the downstream (9) side of the filter/
regulator, the secondary pressure increases.
The secondary pressure is sensed on the under-
side of the diaphragm. As the controlled pres-
sure varies, so does the force on the underside
of the diaphragm. When this force (proportional
to the secondary pressure) equals the compres-
sion in the main control spring, the main valve
will shut. Any fall in secondary pressure will
cause the main valve to open sufficiently to meet
the air flow requirements and accurately main-
tain the set secondary pressure.

1

2

11

10

4

5

6

9

16

12

8

3

13

7

Содержание Spirax-Monnier MP

Страница 1: ...mi nated compressed air 3 is directed to the inside of the bowl 5 by the multi bladed whirl disc 4 Thepreliminaryseparationallowsmost of the liquids and the larger solid particles to pass down into the sump 6 away from any turbulence The air is then filtered by a 5 micron element 7 before flowing past the main valve 8 of the regulator portion of the MP2 With the adjustment knob 1 rotated fully ant...

Страница 2: ...nto contact with the bowl Certain compressor lu bricating oils also contain additives harmful to polycarbonate and where there is any doubt we recommend in the interest of safety that a bowl guard be fitted Spare parts AVAILABLE SPARE Bowl Assembly A B Element Set 5 micron pkt 3 B C Bowl Guard Assembly X Y Z Panel Bracket Mounting Ring D How to order Example 1 Element Set for Spirax Monnier Filter...

Страница 3: ...imum pressure range of the main Control Spring The gauge will indicate the downstream or controlled pressure 4 Ensure that the Control Spring range for RegulatorsandFilter Regulatorsfullymeets the pressure requirements of the system 5 There are Maximum Operating Pressures andMaximumOperatingandEnvironmental Temperatures for each product These are shown in the table below 6 Adequatespaceshouldbepro...

Страница 4: ...P054 04 RANGES 0 2 2 0 0 3 4 0 0 7 9 0 bar 1 3 LUBRICATORS ML3 10 50 1 3 P052 07 IL1 10 50 17 80 17 70 1 2 P059 01 SL3 17 80 17 70 1 3 P052 04 OTHER PRODUCTS IFM2 10 50 1 2 P580 01 S M S 17 70 C 1 3 P050 17 BALL all to 15 bar 45 C VALVES all see performance graph on TI for full details 1 4 P560 01 DRI LINE 16 80 C 1 3 P050 07 DISPOSAL 1 Some plastic and or rubber components 2 Main body Zinc epoxy ...