Spirax Sarco PA420 Скачать руководство пользователя страница 5

IM-P402-139 

 AB Issue 1

5

1.4  Hazardous liquids or gases in the pipeline

Consider what is in the pipeline or what may have been in the pipeline at some 

previous time. Consider: flammable materials, substances hazardous to health, 

extremes of temperature.

1.5  Hazardous environment around the product

Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, 

extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive 

noise, moving machinery.

1.6  The system

Consider the effect on the complete system of the work proposed. Will any proposed 

action (e.g. closing isolation valves, electrical isolation) put any other  part of the 

system or any personnel at risk? 

Dangers might include isolation of vents or protective devices or the rendering 

ineffective of controls or alarms. Ensure isolation valves are turned on and off in a 

gradual way to avoid system shocks.

1.7  Pressure systems 

Ensure that any pressure is isolated and safely vented to atmospheric pressure. 

Consider double isolation (double block and bleed) and the locking or labelling of 

closed valves. Do not assume that the system has depressurised even when the 

pressure gauge indicates zero.

1.8 Temperature

Allow time for temperature to normalise after isolation to avoid danger of burns.

1.9  Tools and consumables

Before starting work ensure that you have suitable tools and/or consumables

available. Use only genuine Spirax Sarco replacement parts.

1.10  Protective clothing

Consider whether you and / or others in the vicinity require any protective clothing 

to protect against the hazards of, for example, chemicals, high / low temperature, 

radiation, noise, falling objects, and dangers to eyes and face.

1.11  Permits to work

All work must be carried out or be supervised by a suitably competent person.

Installation and operating personnel should be trained in the correct use of the 

product according to the Installation and Maintenance Instructions.

Where a formal 'permit to work' system is in force it must be complied with. Where 

there is no such system, it is recommended that a responsible person should know 

what work is going on and, where necessary, arrange to have an assistant whose 

primary responsibility is safety.

Post 'warning notices' if necessary.

Содержание PA420

Страница 1: ...Preamplifier Installation and Maintenance Instructions 1 Safety information 2 General product information 3 Installation 4 Wiring 5 Commissioning 6 Maintenance 7 Fault finding 8 Technical data IM P402...

Страница 2: ...IM P402 139 AB Issue 1 2...

Страница 3: ...l or National standards and regulations Guidance Notes Health and Safety Executive BG01 and INDG436 in the UK The requirements of Approvals Authorities Boiler inspection bodies Boiler manufacturer s s...

Страница 4: ...aximum and minimum values If the maximum operating limits of the product are lower than those of the system in which it is being fitted or if malfunction of the product could result in a dangerous ove...

Страница 5: ...uble block and bleed and the locking or labelling of closed valves Do not assume that the system has depressurised even when the pressure gauge indicates zero 1 8 Temperature Allow time for temperatur...

Страница 6: ...ion must be made to protect products which are not self draining against frost damage in environments where they may be exposed to temperatures below freezing point 1 15 Disposal Unless otherwise stat...

Страница 7: ...irax Sarco and standard industrial controls which are used to control or monitor level It has two buttons and a dual coloured light red and green for use at commissioning It consists of a tubular aust...

Страница 8: ...the preamplifier to the probe and hand tighten only 3 Installation Fig 2 4 Wiring 4 1 General information Cabling should be installed in accordance with BS 6739 Instumentation in Process Control Syste...

Страница 9: ...Screen Loop Internally connected to PA420 body earthed DO NOT connect to any other earth Follow the installation instructions of the instrument the PA420 is connected to 4 3 Cable socket To unplug the...

Страница 10: ...ion span To configure the water levels Step 1 Set the water level to the desired 4 mA or 20 mA level Step 2 Press the 4 mA or 20 mA button for three seconds Step 6 Repeat the above to configure the se...

Страница 11: ...on For specific testing instructions for Spirax Sarco systems please see separate literature 100 20 mA Absolute maximum safe water level Set point 50 0 4 mA Absolute minimum water level water must alw...

Страница 12: ...age across terminals 1 and 2 and ensure it is within specification See Section 8 3 Check the polarity of the supply Plug the connector back in Check the loop current is within specification See Figure...

Страница 13: ...eplacement product follow the actions in Section 7 1 Generic faults 3 Light flashes red 3 times repeatedly and alarm output Level input was too high The measured level signal from the LP20 was too hig...

Страница 14: ...ogether The level input was not saved in memory 1 2 3 Check the button has not been damaged Check around the product to ensure that nothing is pressing on the buttons Follow the actions in Section 7 1...

Страница 15: ...5 6 Light flashes red 6 times repeatedly Watchdog timeout The internal microcontroller has briefly stopped and recovered automatically 1 2 Follow the actions in Section 7 1 Generic faults Monitor data...

Страница 16: ...ipment being returned 3 Full description of the fault or repair required 4 If the equipment is being returned under warranty please indicate a Date of purchase b Original order number 8 2 Limiting con...

Отзывы: