![Spirax Sarco DP143 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/spirax-sarco/dp143/dp143_installation-and-maintenance-instructions-manual_1347916007.webp)
IM-P006-07
CTLS Issue 12
7
0
0
100
200
300
350
10
17.2 20
26
30
40
2.1.2 Pressure/temperature limits
Pressure bar g
Te
mp
er
atu
re
°
C
A
B
F
Steam
saturation
curve
D
E
G
C
The product
must not
be used in this region.
Use the high temperature DP143H version in this region.
A
-
D
-
E
Flanged EN 1092 PN40, ASME 300 and BS 10 Table J.
A
-
B
-
C
Flanged ASME 150.
F
-
G
DP143G limited to 120
°C @ 26 bar g.
Note:
Two colour coded pressure adjustment springs are available for the following downstream pressure
ranges:
Red
0.2 bar g to 17 bar g
Grey
16.0 bar g to 24 bar g
Body design conditions
PN40
Maximum design pressure
A
-
D
-
E
40 bar g @ 40
°C
A
-
B
-
C
17.3 bar g @ 40
°C
Maximum design temperature
350
°C @ 24 bar g
Minimum design temperature
0
°C
Maximum upstream pressure for saturated steam service
A
-
D
-
E
28 bar g
A
-
B
-
C
14 bar g
Maximum operating temperature
DP143
300
°C @ 25 bar g
DP143G
120
°C @ 26 bar g
DP143H
350
°C @ 24 bar g
Minimum operating temperature
Note:
For lower operating temperatures consult Spirax Sarco.
0
°C
Maximum differential pressure
A
-
D
-
E
28 bar
A
-
B
-
C
14 bar
Designed for a maximum cold hydraulic test pressure of:
60 bar g
Note:
With internals fitted, test pressure must not exceed:
40 bar g
Содержание DP143
Страница 2: ...IM P006 07 CTLS Issue 12 2...
Страница 28: ...IM P006 07 CTLS Issue 12 28...