Colima Visco and Viscorol Magnetic level indicators
TI-P329-01
CH Issue 1
Page 7 of 8
Product selection and order placement
Each unit is identified by a unique alphanumeric code that defines the manufacturing characteristics that best suites the application.
Please confirm the following information before commencement of the product configuration.
Process pressure =
Process temperature =
Design pressure =
Design temperature =
Fluid type =
Specific gravity of fluid =
Viscosity of fluid =
Range
Colima
Colima
Model
V
Visco
V
R
Viscorol
Type
LL
Side / side mounted
LL
LF
Side / base mounted
LT
Side / top mounted
TF
Top / base mounted
R
Top insertion only
GV
only Colima Visco type
GDV
only Colima Visco type
Body diameter
Ø 25
(only R type)
60
Ø 50
Ø 60
Ø 70
Indicator body material
Steel
2
1
304L stainless steel
(-25°C to 350°C)
2
316L stainless steel
(-25°C to 350°C)
3
316Ti stainless steel
(-25°C to 350°C)
Plastic
4
PVC
(-20°C to 70°C)
5
PP
(-20°C to 105°C)
6
PVDF
(-20°C to 135°C)
Centre-to-centre measurement
Insert required distance
700
Scale
N
Neutral (no indication)
G
Graduated (every 10 mm)
V
Volumetric (customer to specify)
Connection type
FL
Flanged
FL
TH
Screwed
SW
Socket weld
BW
Butt weld
Attachment rating
UA
UA
Float material
A
316L stainless steel
(-25°C to 350°C)
A
B
316Ti stainless steel
(-25°C to 350°C)
C
Titanium
(-25°C to 350°C)
D
Hastelloy
(-25°C to 350°C)
E
PVC
(-20°C to 70°C)
F
PP
(-20°C to 105°C)
G
PVDF
(-20°C to 130°C)
H
Buna N
(-20°C to 80°C)
Valves
A
Drain valve
A
B
Vent valve
Electrical equipment switches
1
SPDT
2
2
DPDT
SPDT contact number
from 1 up to 8
DPDT contact number
from 1 up to 4
Electrical equipment transmitter
T5
5 mm
T10-A-C3
T10
10 mm
T20
20 mm
A
Housing for safe area (weatherproof)
C
Housing for safe area, low / high temperature
B
Housing for hazardous area (ATEX II ½ G EEX d IIC)
C3
Converter for safe area
C4
Converter for in built safe area (intrinsically safe)
C5
Converter HART
®
protocol (intrinsically safe)
Isolation valve
(wafer type)
F
Flanged
F
T
Threaded
C
Carbon steel body, st. st internals
S
S
Complete stainless steel
Isolation valve quantity
Q
Quantity
Q2
How to order example
:
1 off Spirax Sarco Colima Visco V-LL-60-2-700-FL-UA-A-A-2-T10-A-C3-F-S-Q2.