USER AND INSTALLATION INSTRUCTIONS 

 

WARNING 

 

This appliance must be installed by an authorised person.

 

 

Only use this appliance in a well ventilated area. 

 

Read the instructions before use. 

 

SPINFLO LIMITED, 19 Oakham Drive, Parkwood Industrial Estate 

Rutland Road, Sheffield S3 9QY, ENGLAND. 

TEL: + 44 (0) 114 273 8157     FAX: + 44 (0) 114 275 3094

 

FOR USE IN 

GB NL DE FR ES PT IT SE NO DK SI SK 

BUILD-IN 

COMBINATION UNITS 

MODEL:  S~656/MK 12

  

FOR USE WITH LIQUIFIED PETROLEUM GAS 

 

 

 

 

Содержание S-656/MK 12 series

Страница 1: ... use this appliance in a well ventilated area Read the instructions before use SPINFLO LIMITED 19 Oakham Drive Parkwood Industrial Estate Rutland Road Sheffield S3 9QY ENGLAND TEL 44 0 114 273 8157 FAX 44 0 114 275 3094 FOR USE IN GB NL DE FR ES PT IT SE NO DK SI SK BUILD IN COMBINATION UNITS MODEL S 656 MK 12 FOR USE WITH LIQUIFIED PETROLEUM GAS ...

Страница 2: ...2 ...

Страница 3: ...e mechanical extractor hood Prolonged intensive use of the appliance may call for additional ventilation for example opening a window or more effective ventilation for example increasing the level of mechanical ventilation where present The room containing the cooker should have an air supply in accordance with local and national European standards Position This appliance must be positioned free f...

Страница 4: ...burners should flame as follows Propane The flames should burn quietly with a blue green colour with no sign of yellow tips Butane Normally on initial lighting a small amount of yellow tipping will occur and then slightly increases as the burner heats up Using the Grill Control of the grill burner is identical to that used for the hob burners Although the grill does heat up quickly it is recommend...

Страница 5: ...hat the holes do not become blocked The control knobs are a push fit and can be removed for cleaning They are interchangeable without affecting the sense of operation On units fitted with battery spark ignition when the time taken for spark generation becomes extended the battery should be renewed with a suitable make of long life battery THIS APPLIANCE MUST NOT BE MODIFIED OR ADJUSTED UNLESS AUTH...

Страница 6: ... with a grill require that a grill compartment be created below the cut out as shown in Fig 4 The compartment must be completely lined with a non combustible material such as aluminium or stainless steel The grill compartment must have ventilation holes at the compartment floor level and additionally include an escape route to the outside to prevent the accumulation of unburnt gasses Any cabinets ...

Страница 7: ...the burner mixing tube Replace refit using the reverse procedure Thermocouple removal replacement Shut off gas supply and disconnect gas supply pipe from the unit Remove the hob from the bench top Unscrew the appropriate thermocouple nut next to the burner From the underside of the hob unscrew the appropriate thermocouple nut at the gas valve Remove the thermocouple Replace refit using reverse pro...