![spidocook CALDOBAKE L4 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/spidocook/caldobake-l4/caldobake-l4_instruction-manual_1347348013.webp)
Electrical connections
a- Connection to the power mains must be done following the regulations in force. Operate
the appliance at a room temperature b5°C and +35°C. Make sure that voltage and
frequency values correspond to those indicated on the ratings plate on the oven before
connecting it to the power mains.
The appliance must be positioned in such a way as to allow easy access to the power plug.
As regards for ovens equipped with plug-free power cord, install a single-pole switch
between the appliance and the power mains that can be accessed after installation; the
switch contacts must have a 3 mm minimum gap and be of appropriate load capacity. We
recommend using a differential magneto-thermal switch. Check that the power supply
voltage does not deviate from the nominal voltage value specified on the appliance rating
plate by more than ± 10%.
The safety thermostat protection must be tightly secured so that it cannot be removed
without the aide of a tool.
b- The appliance must be connected to the mains ground line.
In addition, the appliance must be included within an equipotential system, whose efficacy
must be appropriately checked according to the regulations in force. This connection must
be performed between different appliances with the terminal marked with the symbol:
The appliance must be included within an equipotential system, whose efficacy
must be appropriately checked according to the regulations in force. Equi-
potential connection consists in connecting the oven electrically with other
electrical appliances in order to bring the different electrical ground lines to the
same electric potential. The equipotential connection symbol is placed near
the terminal to use for the equipotential connection. The equipotential wire
must have a minimum cross-section of 10 mm2 and be yellow-green.
1- Ovens equipped with Schuko plug (230V single-phase): simply insert the plug into the
power socket (the socket must fit the power plug provided)
2- Ovens equipped with power cord (400V, 3-phase + Neutral): these ovens have a 5-wire
power cord: it is necessary to connect the appropriate 5-pole, 3-phase plug of adequate
load capacity or connect the cord directly to an electric board.
The power supply cable may be replaced for ovens equipped with a 5-pole cable in order to
adapt the oven to the type of electrical current supplied. Follow the procedures below to
replace the power supply cable:
- Open the terminal board cover by prying open
with a suitable screwdriver from the two side
flaps (1)
- Undo the wire fastening screws (2) -Unscrew
the cable clamp screw (3)
- Remove the cable supplied
- Connect the wires of the cable preferred by
following the selected wiring diagram;
make sure to tightly secure the terminal screws
- Secure the cable using the cable clamp
- Close the terminal board cover again
13
English
CALDOBAKE
TM