SpiderCloud Radio Node - SCRN-310 Hardware Installation Guide
SpiderCloud Wireless, Inc.
12
Use
to determine the maximum distance between radio node units. Greater separation may affect
coverage or system performance.
Installation and Mount Bracket Assembly
The radio node has a pedestal base that slides into a long bracket for ceiling or wall mounting. SpiderCloud
Wireless pre-bolts the pedestal base onto the extrusion plate on the radio node. However you must attach
the pedestal base to the mount bracket as shown in
:
Figure 9
Pedestal Base Slides into Mount Bracket
Table 2: Recommended Radio Node Separation Distances
Type of Building
Max Recommended Separation
Warehouses and large open-spaced buildings
70 m (230 feet)
Open-plan offices
45 m (148 feet)
Closed-plan offices (e.g., individual rooms - plasterboard)
30 m (98 feet)
Closed-plan offices (e.g., individual rooms - stone/brick/concrete) 20 m (66 feet)
Mount Bracket
Pedestal Base