52 Operations Manual
–
Wall Extruder (Frame Nailer Gen IV and Tables)
11
Maintenance
Before attempting any maintenance on the Wall Extruder, isolate from air supply; ensure all moving
parts are turned off; and isolate power to the machine.
Table 21, Maintenance intervals
Check
Day Week Month
½ Year
Guards in place
x
Oil level in lubricators
x
Work area is clear
x
Clamp operation
x
Clamp sensor
x
Clean Wall Extruder of any build up
x
Noises or Vibrations
x
Emergency stop working
x
Drain moisture from air reservoir
x
Air supply pressure
x
Pneumatic Filter
x
Nog Trolley assemblies in good condition
x
Carriage assemblies in good condition
x
For loose or damaged bolts
x
Floor bolts for tightness
x
Guide Trolley Slides
x
Bench Top
x
Brake material on Floating carriage and Nog trolleys
x
Inspect the Wall Extruder
x
Maintain Nail Guns
x
(or as required)
Failure to perform these checks as per schedule indicated in Table 21 may result
in severe damage or a serious accident.
WARNING!
Electrical power and Pneumatic Air supply must be isolated from
machinery and appropriate danger tagging in place whenever any maintenance is
being performed on machinery. Any defects, which are found on inspection
should be rectified immediately and reported to the supervisor for appropriate
action.
Содержание Wall Extruder
Страница 1: ...OPERATION MAINTENANCE MANUAL ...
Страница 68: ...67 Operations Manual Wall Extruder Frame Nailer Gen IV and Tables Figure 25 Electrical Drawings Part 2 ...
Страница 69: ...68 Operations Manual Wall Extruder Frame Nailer Gen IV and Tables Figure 26 Electrical Drawings Part 3 ...
Страница 70: ...69 Operations Manual Wall Extruder Frame Nailer Gen IV and Tables Figure 27 Electrical Drawings Part 4 ...
Страница 71: ...70 Operations Manual Wall Extruder Frame Nailer Gen IV and Tables Figure 28 Electrical Drawings Part 5 ...
Страница 72: ...71 Operations Manual Wall Extruder Frame Nailer Gen IV and Tables Figure 29 Electrical Drawings Part 6 ...