SPI Lasers redPOWER Скачать руководство пользователя страница 1

Not to be distributed without prior consent of SPI Lasers UK Ltd. 

 

Slide: 1

 

FS-S00149-Rev A 

redPOWER PRISM OEM 

 

 

 

 

 

 

Prism Module Fiber Laser  

Quick Start Guide 

29/06/2016 

Содержание redPOWER

Страница 1: ...Not to be distributed without prior consent of SPI Lasers UK Ltd Slide 1 FS S00149 Rev A redPOWER PRISM OEM Prism Module Fiber Laser Quick Start Guide 29 06 2016...

Страница 2: ...ustomer Requirements Pre Install RS232 485 Communication Customer Requirements Pre Install 37 Way Dsub Connections Customer Requirements Pre Install Protective Conductor Earth Customer Requirements Pr...

Страница 3: ...leak free and tested before electrical operation of the laser SPI recommend that an appropriate filter is installed in line to the flow lines of the laser The grade of filter is 100 m Pre treated wate...

Страница 4: ...Cooling Water Requirements Parameter Min Max Units Notes Cooling Water Temperature 18 30 C It is important that condensation will not occur Refer to Section 15 1 of SM S00481 redPOWER Prism OEM Fibre...

Страница 5: ...tem the Laser Integrator should consider the following Deionised water is not permitted in the cooling circuit as the generally high levels of dissolved O2 and CO2 in deionised water cause corrosion D...

Страница 6: ...ed with a source of clean chilled water in accordance with the specifications in the table above Operating the PIPA Q optical connector without an adequate flow of cooling water may result in catastro...

Страница 7: ...liary power supply SPI Lasers recommends the following DC power supplies for the pump diode supply Customer sourced Power Supply Customer must follow Supplier instruction Manual for Parallel Operation...

Страница 8: ...he input current can change from 0A to 135A in less than 5 s If the PSU cannot respond fast enough additional capacitive support will be required to ensure that the output power is maintained over the...

Страница 9: ...the Prism OEM module 9 Way Dsub x 2 for RS232 485 Cable The RS232 cable is required for the Customer to communicate with the Prism OEM using the PrismView Graphical User Interface program provided wi...

Страница 10: ...e distributed without prior consent of SPI Lasers UK Ltd Slide 10 FS S00149 Rev A Customer Requirements Pre Install RS232 485 Communication Cable 29 06 2016 RS232 Communication Cable RS485 Communicati...

Страница 11: ...here is no continuity between the FCMS pins on the user interface connector the Prism Fibre Laser is disabled and the industrial laser machine is put in a safe state To help the customer the following...

Страница 12: ...egative side of the circuit to chassis Ground single star point 37 way Dsub Connector The Bus Bars for the DC input power supply must be connected from Negative to Machine chassis Ground Single star p...

Страница 13: ...l the following actions must be undertaken before removal of the laser from the container Inspect the shipping container for any damage Record all damage for insurance purposes The Prism Fiber Laser w...

Страница 14: ...equired Inspect the Prism Laser for any signs of damage Inspect the Optical Connector and the full length of the conduit for any damage Confirm all items have been delivered as per the shipping list i...

Страница 15: ...n take the weight of the Prism unit Bolt the front panel to the cabinet mountings Shelf and 19 Rack Ensure the shelf thickness can take the weight of the prism unit Bolt the front panel to the cabinet...

Страница 16: ...e male connector Connect the protective earth from Item 1 to machine chassis ground Connect the power supply Negative cable Item 3 Ensure the negative terminal of the power supply is also connected to...

Страница 17: ...ics Turn on 24V Auxiliary Supply to Laser Control Turn on Diode Power Supply Starting the Operation Set ENABLE High Laser Ready O P High Set POWER SET High 0 5 to 10V 5 to 100 Power Set MODULATE High...