background image

SPHINX

    Myth 9 Mk2 

 

 

 8 

  

 

 
 

 

4. INSTALLATION AND CONNECTIONS 

 

Installation 

The Myth 9 Mk2 will not become very hot, so 
placement is not critical, although you should not 
place it on top of or near other heat-radiating 
equipment (such as power amps) or in direct 
sunlight. 
If you use the CD player in a closed cabinet or on a 
bookshelf, please ensure unrestricted ventilation 
around the component. 
To prevent any possible interference keep power 
supply cables away from all audio cables. 
If all these conditions are met, the Myth 9 Mk2 will 
perform to the extremely high standards it is 
designed for. 

Connecting the mains cable 

Before you connect the cable please check 
whether the mains voltage indicated on the 
manufacturer’s label on the rear panel is the 
same as your local mains voltage.

  

If not: please contact your dealer and do not 
connect the component to the mains.  
 
You switch the CD player on or off with the 

??

STBY 

button. This way the electronic circuits will be kept 
at optimum working temperature so you can enjoy 
maximum audio quality immediately after switching 
on. Additionally it significantly increases the life 
span of the component. 
 
Connect the mains cable after you have connected 
all other components in the system and have 
double-checked all connections (see Chapter 5.). 

Audio connections 

Before you start connecting equipment it is always 
wise to check whether all the mains power cables 
of all components are disconnected from the mains 
outlets!  
This will prevent any damage to the loudspeakers 
and amplifiers caused by incorrect wiring or 
settings. 
 
Make sure you connect L and R properly. Most cinch 
cables use Red for the Right channel and White or 
Black for Left.  
The cinch connectors on the Myth 9 Mk2's rear 
panel have a red centre for the right channel and a 
white one for the left channel.  
 
When making the connections please refer to the 
descriptions for parts 1. to 5. on page 5. 

 

Connecting the pre-amp 

Connect OUTPUT L and R (1) to the appropriate CD 
IN connectors of the amplifier using a normal cinch 
cable (but of top quality!). 

Connecting the optical cable 

The Myth 9 Mk2 has a CONTROL IN and a 
CONTROL OUT optical jack. It can therefore be 
remotely switched on and off by another Sphinx 
component and it can also remotely switch other 
Sphinx components to stand-by. 
 
When the CONTROL OUT of another Sphinx 
component (most likely the pre-amp) is connected 
to the CONTROL IN (2) of the Myth 9 Mk2, you do not 
have to use the O / I  switch (5). The CD player will 
automatically select Stand-by mode as soon as the 
other component is set to stand-by.  
Through the CONTROL OUT (2) this control signal 
may be sent to other Sphinx components (e.g. 
tuner, power amps, etc.).  
Ensure proper connection of the optical cables, 
otherwise the LED next to the 

??

STBY button (7) on 

the front panel may remain off even though the 
stand-by mode is activated.  
 
If the Myth 9 Mk2 is placed in strong direct sunlight 
the stand-by mode may self-activate. In that case 
you should place the supplied dummy connector in 
the CONTROL IN (2) (but only if this is not being 
used). 

Содержание MYTH 9 MK2

Страница 1: ...1 USER MANUAL MYTH 9 MK2 CD PLAYER STOP PREV T IME SHU F REPEAT ST BY PL AY NEXT PAUSE PROG PEAK OPEN...

Страница 2: ...CD 9 Different time display 9 Playing a different track 9 Playing tracks in a different order 9 Program Play PROG 9 Programming tracks 9 Playing the programmed tracks 10 To stop Program Play 10 Shuff...

Страница 3: ...ntegrated power line suppression filter this ensures an extremely high S N ratio In addition to the usual functions like Program Repeat and Shuffle Play the Myth 9 Mk 2 also offers a Peak Fade mode fo...

Страница 4: ...age please contact your Sphinx dealer immediately and retain all packing materials for possible proof of damage and possible claims Even if the component is in perfect condition you should still keep...

Страница 5: ...unction on LED is off off LED is red 8 Receptor window for the IR signals from the Remote Control 9 Display This will show all important data more information can be found on page 6 10 PLAY To start p...

Страница 6: ...t data for the component such as serial number and mains power voltage 4 Warning This shows important information about the safety regulations for the Myth 9 Mk2 5 AC Power Connect the mains cable to...

Страница 7: ...programmed tracks will light As soon as a track has been played during any Play mode the track number will be extinguished So only the remaining tracks tot the last one will be lit 4 PAUSE Indicates...

Страница 8: ...isconnected from the mains outlets This will prevent any damage to the loudspeakers and amplifiers caused by incorrect wiring or settings Make sure you connect L and R properly Most cinch cables use R...

Страница 9: ...e NEXT button 4 times The display shows the new track number left and in the 1 15 line the numbers from track 5 to the last will be lit Each press on the PREV button will select the previous lower num...

Страница 10: ...o press the PAUSE button The CD player first locates the start position of the first programmed track and then selects Pause mode This might be handy when recording a tape You first can select the rec...

Страница 11: ...signal is sent to the output You can now simply adjust the recording level of the recorder to the maximum value So you don t have to worry about sudden signal peaks causing distortion or noise caused...

Страница 12: ...ut in reverse With a slight push you can fix the CD in the box under the clamp Never place CD s anywhere unprotected but transfer it straight from the player to their proper box Never touch the shiny...

Страница 13: ...Hz 0 0 2 dB Phase response error 0 3 THD N IHF A 0 004 2nd harm 10 20 000 Hz IMD 0 01 S N ratio IHF A 106 dB Channel separation 70 dB Output section Class A discrete throughout Outputs 2x cinch gold...