CC335/CC355
3. Equipment Operation
3.1 Command Description
– Normal Operation
Display
The two digit numeric display is used for informing the operator about the selected set temperature.
Set-Point
The set-point is the desired temperature inside the vehicle. The actual selected set point temperature blinks and may be adjusted by
pressing the or keys.
Automatic Mode
1 - To select the Automatic Mode press the key.
In the Automatic Mode the controller will automatically chose one of the available functions (cooling or heating), according to the
set point temperature.
2
– To disable the Automatic Mode, press the key again.
Ventilation Mode
The Ventilation function is activated by pressing the key.
There are two operation speeds. Press the key once to select the
LO
ventilation speed, press the key a second time to
select
HI
ventilation speed.
Cooling Mode
After selecting the Automatic Mode and the internal temperature of the vehicle is above the desired set point, the system will start
operating in the cooling mode and selects the evaporator blower speed automatically.
When the system starts up in the cooling mode the
evaporator’s blowers will start in the automatic mode according to the set point
programming. Ventilation speeds may be changed manually with the key.
11
7