3. Precautions: 

If it is 12V system, the bottom left corner of LCD display will show '12V', 24V system will show' 24V',

 

 

  The first step is to connect the battery. If the connection is made correctly, the controller screen will light 

up; otherwise, check whether the connection is correct. 

  The second step is to connect the solar panel. If sunlight is present and strong enough (the solar panel 

voltage   

is greater than battery voltage), the sun icon on the LCD screen is on; otherwise, check whether the 

connection is   

correct (it's recommended that the operation be performed under the debugging mode). 

  The third step is to connect the load. Connect the load leads to the controller's load output terminal, and 

the   

current shall not exceed the controller's rated current. 

As the controller will generate heat during operation, it's recommended that the controller be installed in 

an   

environment with good ventilation conditions. 

  Choose cables with large enough capacity for connection, in case too much loss incurred on the lines 

causes   

the controller to misjudge. 

  The controller has a common positive pole inside. If grounding is needed, ground the positive pole. 

  It's important to fully charge the battery regularly. At least once full charging every month is 

recommended, and failure to do that may cause permanent damage to the battery. Only when in-flow energy 

outpaces out-flow energy can the battery be charged fully. Users shall bear this in mind when configuring 

the system. 

  Check whether the controller's each connection terminal is tightened securely; if not, it may suffer 

damage when large current passes. 

15. Error Code List 

Code on LCD screen

 

Corresponding error

 

E0 

No error

 

E1 

Battery over discharge 

E2 

Battery overvoltage

 

E3 

Undervoltage warning

 

E4 

Load short circuit

 

E5 

Load overload

 

E6 

Temperature too high inside controller

 

E8 

Charging current too high

 

E10 

Solar panel input voltage is too high

 

Содержание PWM Series

Страница 1: ...PWM Solar Charge Controller User Manual ...

Страница 2: ...tion of lithium batteries 5 A wide range of load working modes facilitate the product s application to different types of street lights and monitoring devices Some loads can have excessive start up currents that can trip the logic of the controller if using for Load connection please consult your dealer firstly to ensure the current startup or peak current does not exceed the rating of the control...

Страница 3: ...10 minute delay settable to confirm the starting signal and then switches on the load for operation When sunlight emerges and the light intensity reaches the starting point the controller initiates a 1 minute fixed delay to confirm the shutting down signal and then shuts down the output to stop the load s operation 2 Light control time control 1 to 14 The starting process is the same as pure light...

Страница 4: ...n the load mode menu long press for 2s and the number e g 15 will begin to flash Press to adjust the mode from 0 to 17 and then long press again for 2s to complete and save the setting Note 1 After parameter adjustment if is not pressed and held long enough for exiting the system exits to the main menu after 12s and the parameter that was set is not saved 2 When the system is saving data the scree...

Страница 5: ...eep the battery away from fire sparks as the battery may produce flammable gas 6 Keep children away from the battery and controller 7 Follow the safety advice provided by the battery manufacturer 7 LCD Screen Illustration 8 Browsing Menu on LCD Screen 1 Continuously press the screen will display the following in order main menu solar panel voltage solar panel current battery capacity battery volta...

Страница 6: ...tings or the first to enter charging voltage setting menu for lithium battery 3 After parameters have been set long press for 2 s to save and exit parameters shall be set according to the following rule over discharge voltage over discharge return voltage under voltage warning floating charging voltage boost charging return equalizing charging voltage overcharge voltage and two adjacent values sha...

Страница 7: ...ext day or long press to make the load resume output 13 Communication Port Line Sequence Only for Controllers with Communication Functions Controller communication port RJ12 6 pin 14 Installation Instructions and Precautions 1 The controller shall be installed securely and its dimensions are as follows 2 Installation hole diameter 3 2 mm ...

Страница 8: ... be installed in an environment with good ventilation conditions Choose cables with large enough capacity for connection in case too much loss incurred on the lines causes the controller to misjudge The controller has a common positive pole inside If grounding is needed ground the positive pole It s important to fully charge the battery regularly At least once full charging every month is recommen...

Страница 9: ... high The battery icon flashes slowly and there is no output The battery is over discharged and will recover when recharged adequately The load icon flashes quickly and there is no output The load s power exceeds the rated value or it s short circuited After removing the problem long press the key or wait until it recovers automatically The load and the encircling light ring stays lit and there is...

Страница 10: ...Boost charging time 2H Temperature compensation 3 0mV 2V Light control voltage Light control on 5V light control off 6 V light control on plus 1 V 1 12V 2 24V Light control judgment time 10 minutes USB function Yes Operating temperature 25 to 55 IP protection degree IP30 Net weight 390g Protection functions Battery plate reverse connection protection a battery reverse connection protection chargin...

Страница 11: ...e relevant maintenance schedules 3 2 The claim listed in clause 3 1 may be made in person or the claim may be sent to the address listed on this form including the particulars required under clauses 3 1 i and 3 1 ii 3 3 The appropriate form for making a claim for warranty is as attached 4 DURATION OF WARRANTY 4 1 This warranty will cease i where the Goods are purchased already fitted in or as a co...

Страница 12: ...install fit maintain service or use the Goods in accordance with the specifications and instructions provided by the Manufacturer including a failure to comply with the relevant maintenance schedule where applicable ii the Supplier cannot establish any Defect in the Goods after testing iii the Goods have been used other than for the purpose for which they were designed iv the Goods have been subje...

Страница 13: ... box Yes No Receipt No Description of defects Give as much detail as possible Use a separate page if required Date of purchase services provided I hereby declare that the information provided above is true and correct and to the best of my knowledge and belief and I have complied with all the conditions of the warranty Signed Name please print Dated Please note the issue or completion of this form...

Отзывы: