Installing the clean room system

6.1

Installing the FMS series SuSi

The FMS series SuSi can be installed in the following locations:

On a machine

Above a table or workstation

On the ceiling of a building

FMS series SuSi installation from above

1

FMS series SuSi

2

Profile frame

3

M6 fillister head screws

1. Position the FMS series SuSi (1) flush on the profile frame (2). The internal dimensions of the profile frame

can be found in the technical data, see 

Chapter 3.5, "Internal dimensions of the frame of the laminar flow

module"

.

2. Screw the FMS series SuSi firmly to the profile frame using M6 fillister head screws (3).
3. Check that the FMS series SuSi is firmly positioned.

6.0 2020

29

Содержание FBS 112 standard

Страница 1: ...Laminar flow systems Translation of the original operating instructions 6 0 2020...

Страница 2: ...Legal notice Legal notice SPETEC GmbH Am Kletthamer Feld 15 85435 Erding Germany Telephone 49 0 8122 95909 0 Fax 49 0 8122 95909 55 E mail spetec spetec de Website www spetec de 2 6 0 2020...

Страница 3: ...a clean room system from Spetec The clean room system is ideal for use in industry and research The following pages provide instructions on proper and careful use of your clean room system as well as...

Страница 4: ...boxes 12 3 3 3 Clean room stations and workstations 14 3 4 Dimensions 15 3 5 Internal dimensions of the frame of the laminar flow module 16 4 Safety 17 4 1 General safety information 17 4 2 Safety equ...

Страница 5: ...ting 40 10 Maintenance 41 10 1 Care and service 41 10 2 Filter change 42 10 2 1 Changing the pre filter 43 10 2 2 Changing the main filter on standalone devices 44 10 2 3 Changing the main filter on c...

Страница 6: ...rectives Product Product description FMS 24 112 2017 Laminar flow module Standards applied Safety EN 292 EN 294 EN 60024 1 EN 954 1 EN 61310 1 Electromagnetic Compatibility EMC EN 55011 2009 Group 1 C...

Страница 7: ...efore commissioning the clean room system They outline the way in which it should be used and point out potential hazards 2 2 Explanation of symbols The clean room cell is not designed for accessing t...

Страница 8: ...with moderate risk This could result in death or serious injury if the risk is not avoided CAUTION Hazard with low risk This could result in minor or moderate injury or material damage if the risk is...

Страница 9: ...ll that takes into account safety and potential hazards Their work shall be briefed checked and overseen by trained supervisory personnel specialist personnel appointed by the operating company Only t...

Страница 10: ...Si M 3 15 A Temperature range 10 C to 50 C Humidity 20 to 80 non condensing Clean room systems with acid resistant fume cupboard EFBS series SuSi EFBS V series SuSi EBS series SuSi Power data for acid...

Страница 11: ...Laminar flow module FMS series SuSi Size Average power consumption at 0 4 m s in W Maximum power consumption in W 37 60 265 56 85 265 75 125 510 93 155 510 112 140 510 FMS series basic Size Average po...

Страница 12: ...n kg Laminar flow module FMS 75 1220 x 610 30 3 3 2 Laminar flow boxes FBS series SuSi Designation Filter dimensions in mm Weight in kg Laminar flow box FBS 37 610 x 610 77 Laminar flow box FBS 56 915...

Страница 13: ...dimensions in mm Weight in kg Laminar flow box EFBS V 37 610 x 610 71 Laminar flow box EFBS V 56 915 x 610 81 Laminar flow box EFBS V 75 1220 x 610 101 Laminar flow box EFBS V 93 1525 x 610 115 Lamina...

Страница 14: ...oy mini maxi Designation Filter dimensions in mm CleanBoy 37 610 x 610 CleanBoy 56 915 x 610 CleanBoy 75 1220 x 610 CleanBoy 93 1525 x 610 CleanBoy 112 1830 x 610 CleanBoy mini maxi basic Designation...

Страница 15: ...series EFBS series PBS series EBS series Size Dimensions in mm 37 645 x 735 56 950 x 1040 75 1255 x 1345 93 1560 x 1650 112 1865 x 1955 The dimensions apply for the following clean room systems Clean...

Страница 16: ...ow module FMS 56 645 950 Laminar flow module FMS 75 645 1255 Laminar flow module FMS 93 645 1560 Laminar flow module FMS 112 645 1865 Internal dimensions of the frame from below Designation Width in m...

Страница 17: ...sk of injury due to voltages on the clean room system This could result in serious injury or death Remove the mains plug of the clean room system before opening the clean room system WARNING Risk of i...

Страница 18: ...personal protective equipment Protective work clothes Protective work clothes are close fitting clothes with low tear resistance narrow sleeves and no protruding parts They are primarily designed to...

Страница 19: ...a risk of direct lightning strike or impact in the vicinity 4 5 Before use Check that the supply voltage matches that on the type plate Observe the legal stipulations for electrical commissioning The...

Страница 20: ...he series of devices is modular in construction which means that individual components are mutually compatible and expandable 5 1 Laminar flow module The following versions of the laminar flow module...

Страница 21: ...flow box 5 2 Laminar flow box 5 2 1 Laminar flow box The following versions of the laminar flow box are available FBS series FBS series standard FBS V series The laminar flow box is designed as a tab...

Страница 22: ...system FBS series The FBS series is a table top device with sliding door and perforated metal shelves FBS series standard The FBS series standard is a table top device without sliding door and perfora...

Страница 23: ...tion of the clean room system FBS V series The FBS V series is a laminar flow module with clean room strip curtain The curtain is 2000 mm long but can be made according to customer specifications 6 0...

Страница 24: ...esistant extraction device The extraction device is connected to a domestic extraction system by a pipe EFBS series The EFBS series is a laminar flow box with integrated acid resistant extraction devi...

Страница 25: ...achment It can be retrofitted with a filter attachment to convert it into a laminar flow box The PBS series is used as a clean room workstation and is designed for dust proof storage of objects 5 4 Ex...

Страница 26: ...s of the clean room station and workstation are available CleanBoy mini CleanBoy maxi CleanBoy basic The CleanBoy comprises a SuSi series laminar flow module and a mounting frame CleanBoy mini The Cle...

Страница 27: ...asic mini The CleanBoy basic mini is a table top device and is equipped with a basic series laminar flow module CleanBoy basic maxi The CleanBoy basic maxi is a standalone device and is equipped with...

Страница 28: ...t reach into mechanical moving parts Conversion work and maintenance may only be carried out with the clean room system switched off and secured against reactivation NOTICE Note the weight and mountin...

Страница 29: ...bove 1 FMS series SuSi 2 Profile frame 3 M6 fillister head screws 1 Position the FMS series SuSi 1 flush on the profile frame 2 The internal dimensions of the profile frame can be found in the technic...

Страница 30: ...nge from below 1 Screw 2 Mounting not included 3 FMS series SuSi 4 Screw 1 Slide the FMS series SuSi 3 through the profile frame from below The internal dimensions of the profile frame can be found in...

Страница 31: ...Secure the four ceiling attachments to the FMS series SuSi 3 Hook the FMS series SuSi into the ceiling mountings 4 Check that the FMS series SuSi is firmly positioned 6 2 Installing the FMS basic WAR...

Страница 32: ...ing frame 5 M6 screws 1 Undo the countersunk screws 2 using a hexagonal screwdriver 2 5 or Torx Tx20 2 Remove the lock plate 1 3 Position the FMS series basic 3 flush on the mounting frame 4 4 Screw t...

Страница 33: ...room strip curtain Consequently the four mounting points on the FMS series SuSi must be attached to a ceiling mounting 1 FMS series SuSi 2 Profile 3 Slot nut 4 Clean room strip curtain 5 Washer 5 Cap...

Страница 34: ...bles NOTICE There is no fixed sequence for connecting the cables Nevertheless Spetec recommends connecting the control cables first and then the cold device plug for the 230 V power supply NOTICE The...

Страница 35: ...d at the time of purchase Please observe the supplementary instructions 1 If necessary connect multiple modules using the control 7 pin 2 If necessary connect a cold device plug to the light output 3...

Страница 36: ...tor Fig 2 Cable connections 7 Remote connection 8 Device fuse 9 Power supply 1 Connect the supplied cold device cable to the power supply 2 Connect the power supply cable to a free socket The clean ro...

Страница 37: ...not touch live parts Do not attach earths to mechanical connecting elements 8 1 SuSi clean room systems NOTICE If call service appears on the display please contact customer services Display Fig 3 4 r...

Страница 38: ...uns at maximum speed The clean room system is flushed eco Flow speed min The clean room system is put into night economy Fan runs on low to continuously flush the clean room system with air filter LED...

Страница 39: ...8 2 Basic clean room systems Controls 1 Mains on off switch 2 Flow speed setting Function Explanation Mains on off switch Switch the fan on off Flow speed setting Continuous adjustment of flow speed 6...

Страница 40: ...ontinuous adjustment of extraction power 9 Troubleshooting WARNING Risk of injury due to restoration of energy supply after an interruption This could result in serious injury or death Troubleshooting...

Страница 41: ...ular intervals Service intervals To ensure consistency of function and quality from the clean room system regular maintenance is essential An annual service of the clean room system by a service techn...

Страница 42: ...rious injury or death Do not stand under the main filter when carrying out a main filter change A filter change must be carried out by two people Do not stand under suspended loads when installing the...

Страница 43: ...h filter grille 3 Filter grille 4 Pre filter 1 Remove the screws 1 2 Remove the pre filter and filter grille 2 3 Slide the pre filter 4 out of the filter grille 3 4 Insert the new pre filter 4 into th...

Страница 44: ...not be subjected to point loads 1 Filter module 2 Main filter 3 Screws 12x 1 Undo the screws 3 inside 2 Lift the filter module 1 upwards 3 Remove the main filter 2 4 Insert the new main filter 2 5 Re...

Страница 45: ...urn when the wing nuts are turned A star grip may be used to hold the threaded rods in position On clean room cells and suspended laminar flow modules the main filter is changed from below To do this...

Страница 46: ...3 can be removed 7 Insert the new main filter 3 Main filter 8 Fit the main filter in reverse order 9 Check that the main filter is firmly seated The laminar flow module can be put back into operation...

Страница 47: ...o prevent contamination with particles 12 Disassembly and disposal 12 1 Disassembly 1 Switch the power supply to the clean room system off at the power switch 2 Physically disconnect the power supply...

Страница 48: ...06 0053 Rear assembly 06 0050 H14 filter FMS 24 11 0302 H14 filter FMS 37 11 0303 H14 filter FMS 56 11 0304 H14 filter FMS 75 11 0305 H14 filter FMS 93 11 0306 H14 filter FMS 112 11 0307 Replacement...

Страница 49: ...rranty for all modules is 24 months Filters and wear parts are excluded from the warranty The warranty period commences on the day of delivery to the end customer No warranty claims shall be accepted...

Страница 50: ...ons Table of abbreviations EBS Spetec exhaust protection box EFBS Spetec exhaust flow box FBS Spetec flow box FBS V Spetec flow box curtain FMS Spetec flow module PBS Spetec protection box SuSi Super...

Страница 51: ......

Страница 52: ...Spetec GmbH Am Kletthamer Feld 15 85435 Erding Germany Telefon 49 8122 95909 0 Fax 49 8122 95909 55 E Mail spetec spetec de Webseite www spetec de Backcover...

Отзывы: