background image

14

3)  Insert  a  new  connector,  threaded  end  first,  from  inside  the  facepiece. 

Push the connector until the threads are clear and the connector flange is 

securely seated.

b. Exhalation Valve Seat and Cover Replacement

1) Remove the exhalation valve cover using the small tab on the cover.

2) Remove the exhalation valve.

3) Remove the valve seat by pushing inward to disengage the seat from the 

facepiece.

4) Insert a new valve seat from inside the facepiece. Securely seat the smaller 

diameter flange by flexing the facepiece material while pressing the seat, 

working the facepiece into the seat groove. 

5) Install a new valve by pulling the stem through the seat until it snaps into 

place.

6) Reinstall the exhalation valve cover.

7) Test the new valve by performing a negative pressure fit check as described 

in section C.

I. STORAGE

WARNING

This SPERIAN respirator does not have a defined storage life. Carefully 

inspect the respirator before each use. Failure to comply with this warn

-

ing may lead to personal injury, illness, or death.

CAUTION

The maximum storage temperature for the respirator is 140°F (60°C). 

Long-term  storage  at  elevated  temperatures  may  cause  premature 

deterioration.

After inspection and cleaning, store the respirator to protect it against dust, 

sunlight, extreme heat and cold, excessive moisture, or damaging chemicals.

J. SHIPMENT

All products returned to SPERIAN’s factory, distributors, or repairs centers must 

be decontaminated before shipment.

Содержание Surviair 2000 Series

Страница 1: ...ng it into service Please refer to the inspection procedures in this manual Failure to comply with this warning may result in personal injury illness or death NIOSH APPROVED SEE SEPARATE APPROVAL LABE...

Страница 2: ...vels SPERIAN cannot predict what will happen to this respirator in every potential environment Materials can be chemically attacked if exposed to the wrong environment and may exhibit excessive corros...

Страница 3: ...1910 134 Appendix C Medical Evaluation Questionnaire or by a medical professional Persons sensitized can have a severe reaction to chemicals at levels well below accepted health levels such as the OSH...

Страница 4: ...t edition If this respirator will be used during welding it is the user s responsibility to obtain the proper equipment for protection against sparks optical radiation and impact This respirator will...

Страница 5: ...efore using a particulate filter you must confirm the atmosphere is non IDLH and not oxygen deficient the contaminant is a particulate hazard and you must determine the hazard ratio hazard concentrati...

Страница 6: ...osphere if one or more of the ESLIs is gray 3 Cartridge Filter Installation a Ensure that you have the correct cartridge and or filter type for the contaminants in your work area If you are not sure c...

Страница 7: ...ts Hand tighten but do not overtighten See inset 1 3 Position the bottom of the facepiece as low as possible under the chin while positioning the narrow portion of the facepiece on the bridge of the n...

Страница 8: ...as a thin sheet of plastic or rubber When the respirator is equipped with cartridges filter retainers may be used as an aid Alternatively the cartridges may be removed to perform the fit check If remo...

Страница 9: ...this warning may lead to personal injury illness or death E CHEMICAL CARTRIDGE SERVICE LIFE AND REPLACEMENT WARNING OSHA allows the use of respirators for protection against contaminants with poor wa...

Страница 10: ...ow to determine the cartridge service life for mixtures please contact SPERIAN Failure to comply with this warning may lead to personal injury illness or death The gas vapor service life depends on th...

Страница 11: ...in the filter resulting in a loss of filter efficiency and the determina tion of when breathing resistance becomes too uncomfortable is subjective Filters should also be replaced in accordance with s...

Страница 12: ...it from the facepiece for inspection 1 Inspect the facepiece skirt for cuts gouges punctures tears nicks and deterioration from age heat or contamination and the face seal area for distortion 2 Inspe...

Страница 13: ...nt type cleaners to clean any part of the respirator Do not use sonic cleaners on respirators equipped with a speaking dia phragm a Remove the cartridges and or filters b Immerse the facepiece in warm...

Страница 14: ...g the stem through the seat until it snaps into place 6 Reinstall the exhalation valve cover 7 Test the new valve by performing a negative pressure fit check as described in section C I STORAGE WARNIN...

Страница 15: ...4 Lower Headband Blue 1 140040 Lower Headband and Upper Cradle Set Blue 1 2 See Note Facepiece Skirt Series 2000 2a See Note Facepiece Skirt Blue 1 w Speaking Diaphragm 2b See Note Facepiece Skirt Blu...

Страница 16: ...anic Vapors 14 100200 Acid Gases 14 100300 Organic Vapors and Acid Gases 14 100400 Ammonia and Methlyamine 14 100600 Mercury Vapor and Chlorine 14 100800 Multi Contaminant 15 1051 Combination Organic...

Страница 17: ...17 Figure 1 Half Mask Facepiece...

Страница 18: ...f defective parts and such other necessary maintenance and repair as may be required Normal wear and tear parts damaged by abuse misuse negligence or accidents and inhalation and exhalation valves are...

Отзывы: