Display 

1/2 

digits, 3/4" LCD 

Functions 

dB ( A and C Frequency Weighting), 
Response (Fast, Slow),  
Max. Hold 
AC/DC Output 

Measurement Range 

30-70 dB, 60-100 dB, and 90-130 dB 
40 dB on each step, with overload indicator 

Resolution 

0.1 dB 

Accuracy 

± 1.5 dB 

Frequency 

31.5 Hz to 8,000 Hz 

Microphone 

1/2" condenser microphone. 

Response (Fast/Slow)

 

Fast (F): t = 200 ms 
Slow (S): t = 500 ms

 

Internal Calibration 

Built-in internal calibration on front panel. 
Internal 94 dB / 1 kHz square wave generator 

Output Signal 

AC:  0.5 Vrms corresponding to each range 
step. DC:  0.3~1.3 VDC, 10 mV per dB. 
Output impedance is 600 ohm. 

Output Terminal 

3.5 mm diameter phone jack  

Operating Temp. 

32~122°F (0~50°C) 

Operating Humidity 

Less than 90% RH 

IV. SPECIFICATIONS

 

Power Supply 

One 9V battery, heavy duty or alkaline type 

Power Consumption 

Approximately DC 6 mA 

Weight 

10 oz. 

Dimension 

8

 

1/8" 

x 3 

1/8" 

x 1 

3/8"

 

Included Accessories 

Instruction Manual, 9V battery, calibration 
screw driver, and hard carrying case 

Optional Services & 
Accessories 

840029C NIST Traceable Cert. of Calibration 
840031

 

Acoustical Calibrator

 

840091

 

Wind Screen 

CE Compliant 

Yes 

- 6 - 

Содержание 840029

Страница 1: ...DIGITAL SOUND LEVEL METER 840029 Instruction Manual ...

Страница 2: ...ructions A Measuring Procedure 4 B Settings for General Applications 4 C Signal Output 4 D Calibration 4 5 E Precautions 5 F Battery Replacement 5 IV Specifications 6 Frequency Weighting A and C Characteristics 7 Response Fast and Slow Characteristics 7 V Warranty 8 2 ...

Страница 3: ...h OSHA using Sper Scientific s Acoustical Calibrator 840031 or equivalent Features include a built in calibration adjustment Fast or Slow time weightings Maximum Hold function large display with a resolution of 0 1 dB low battery indicator and AC or DC output The instrument has a fold out tripod stand and comes with carrying case instructions II PANEL DESCRIPTION Overload indicator Power selector ...

Страница 4: ...NDICATOR a triangle shape appears in the upper left display slide the RANGE selector to another setting Point the microphone at the sound source the sound level will be displayed in decibels dB To power off the unit slide the POWER selector to the OFF position B SETTINGS FOR GENERAL APPLICATIONS Set POWER selector to an ON position Set RESPONSE selector to Fast Set WEIGHTING to A Set RANGE selecto...

Страница 5: ...rator and place the calibrator onto the Sound Level Meter s MICROPHONE Slide the RANGE selector to the 50 100 dB position Slide the RESPONSE selector to FAST Slide the WEIGHTING selector to A Use the calibration screw driver to gently turn the CALIBRATION ADJUSTMENT until the display reads 94 0 E PRECAUTIONS Do not store or operate the unit in high temperatures or in a high humidity environment fo...

Страница 6: ... square wave generator Output Signal AC 0 5 Vrms corresponding to each range step DC 0 3 1 3 VDC 10 mV per dB Output impedance is 600 ohm Output Terminal 3 5 mm diameter phone jack Operating Temp 32 122 F 0 50 C Operating Humidity Less than 90 RH IV SPECIFICATIONS Power Supply One 9V battery heavy duty or alkaline type Power Consumption Approximately DC 6 mA Weight 10 oz Dimension 8 1 8 x 3 1 8 x ...

Страница 7: ...200 10 9 0 2 0 250 8 6 0 2 0 315 6 6 0 2 0 400 4 8 0 2 0 500 3 2 0 2 0 630 1 9 0 2 0 800 0 8 0 2 0 1000 0 0 2 0 1 25k 0 6 0 2 0 2 5 1 6k 1 0 0 1 3 0 2 5 2k 1 2 0 2 3 5 3 0 2 5k 1 3 0 3 4 0 3 5 3 5k 1 2 0 5 4 5 4k 1 0 0 8 4 0 5 0 5 1 3 5 0 4 5 6 3 0 1 2 0 5 5 5 0 8 1 1 3 0 6 0 5 5 RESPONSE Fast and Slow CHARACTERISTICS Fast Reading is maximum value at 0 2 seconds Slow Reading is maximum value at 1 ...

Страница 8: ...l be substituted if available This warranty does not cover damage resulting from accident misuse or abuse of the product In order to obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 7720 East Redfield Suite 7 Scottsdale Arizona 85260 480 948 4448 www sperscientific com Please Note The defective unit must be accompanied by a description of the problem and your return add...

Отзывы: