Sper scientific 80008 Скачать руководство пользователя страница 3

3

INTRODUCTION

Your digital thermometer accurately measures temperature in 

Centigrade or Fahrenheit from -200°C to 1370°C (-328°F to 2498°F).  

It conforms to the National Bureau of Standards and IEC584 

temperature and voltage tables for K-type thermocouple probes.

Features include a data hold function, maximum and minimum value 

recording, memory and clock functions, and a low battery indicator.  

An RS232 interface allows the unit to communicate with a computer.

Applications include HVAC, lab work, environmental work,  

process control, and the food industry. 

PANEL DESCRIPTION

1.  K Type temperature sensor 

input connector

2. LCD Display
3. Power Button
4. Relative Readout Button
5. Record Button
6. Tripod Connector (on back) 
7. Battery Cover (on back)
8. Min/Max Button
9. Hold Button
10. °C/°F Button
11. Offset Calibration Screw
12. Digital Output Connector
13.  AC Power Adaptor 

Connector

1

2

3

4

5

6
7

11

8

9

10

12

13

Содержание 80008

Страница 1: ...Advanced Datalogging Thermometer 800008 Instruction Manual...

Страница 2: ...any means electronic mechanical or other means that do not yet exist or may be developed including photocopying recording or any information storage and retrieval system without the express permissio...

Страница 3: ...ock functions and a low battery indicator An RS232 interface allows the unit to communicate with a computer Applications include HVAC lab work environmental work process control and the food industry...

Страница 4: ...he thermocouple plug into the meter 3 The meter will default to the temperature scale last used Press the C F button to change the temperature scale if necessary 4 Begin taking temperature readings 5...

Страница 5: ...t press the HOLD button again Setting the Recording Interval for Datalogging 1 With the meter turned off press and hold the MAX MIN button 2 Press the POWER button to turn the meter on Release the but...

Страница 6: ...NT The low battery indicator appears when the battery needs replacement Insert a fresh 9V battery PC CONNECTION The Digital Output is a 9600bps N 81 serial interface The RX is a 5V normal high input p...

Страница 7: ...s For example when sending command K to meter it will return 3 0 5 ASCII 13 Command U Return 32768 bytes Command P Instead of returning all 32768 bytes it only returns recorded data Command H Equivale...

Страница 8: ...software The ThermoLog package contains Two 3 5 diskettes Custom designed RS232 cable for THERMOLOG System Required Windows 95 or Windows 98 or Windows NT 4 0 above Minimum Hardware Required 486 100...

Страница 9: ...irectly available to download due to it must be purchased If you find that the software you need is not available please contact our Customer Support at 480 948 4448 or email info sperscientific com f...

Страница 10: ...DataLogger Window the user can load the recorded data from the thermometer Tabular By opening the Tabular window the present data from the thermometer will be listed in a scrolling table These data c...

Страница 11: ...add the following tolerance into the accuracy spec 0 01 of reading 0 03 C 0 01 of reading 0 06 F Probe Temp Range 50 to 300 C 58 to 572 Numerical Display 4 digital Liquid Crystal Display Input Projec...

Страница 12: ...does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will break the waterproof seal an...

Отзывы: