MEASUREMENT PROCEDURE

1.  Press the 

P/Δ button

 for 3 seconds to turn the 

 

meter 

on

 or 

off

2.  The meter will turn 

off

 automatically after 10 minutes 

 

of inactivity. 

3.  To view the Δ (difference) measurement, press the 

 

P/Δ button 

for 0.5 second. The unit will start at zero 

and then display the Δ reading. 

4.  Press the 

P/Δ button

 for 0.5 second to return to 

Normal Mode.

Minimum/Maximum Modes

1.  To change mode, press the 

MIN/MAX button

 for 0.5 

second to cycle through Max, Min and Normal Modes. 

2.  In Min & Max Modes only, press the 

P/Δ button

 to 

reset memory.

3.  Wait 10 seconds and the unit will automatically return 

to Normal Mode. 

4.  The Max/Min data will be reset when the unit is turned off. 

Changing Temperature Scale

1.   To switch the display between °C &°F, use a pointed 

tool (such as a disassembled paper clip) to poke 

straight (perpendicular to the unit, not at an angle) into 

the small hole located on the back of the unit. 

 2.  Press in (you will feel a button push down inside the 

unit) until the LCD display switches the °C/°F display.

Содержание 800012

Страница 1: ...lly updated delta difference from a starting point The pen stands upright on its base enabling unobstructed airflow around the sensor and recalls high and low readings RH Temperature Pen 800012 DESCRIPTION 2 3 4 1 5 1 RH Temp Sensor 2 LCD display 3 P Δ Button 4 Min Max Button 5 Battery 6 Battery Access 6 ...

Страница 2: ...he MIN MAX button for 0 5 second to cycle through Max Min and Normal Modes 2 In Min Max Modes only press the P Δ button to reset memory 3 Wait 10 seconds and the unit will automatically return to Normal Mode 4 The Max Min data will be reset when the unit is turned off Changing Temperature Scale 1 To switch the display between C F use a pointed tool such as a disassembled paper clip to poke straigh...

Страница 3: ... 5V battery ensuring correct polarity SPECIFICATIONS Range Res Accuracy Temp 20 to 60 C 4 to 140 F 0 1 F 0 1 C 1ºC 2ºF RH 20 to 95 0 1 3 fs 30 to 80 RH otherwise 5 Response time 30 to 90 120 seconds 90 to 30 150 seconds Operating temperature 0 to 40 C 90 RH Storage temperature 10 to 60 C 70 RH Dimensions 6 12 8 165 mm Weight 1 7 oz 48 g ...

Страница 4: ...available This warranty does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will void the warranty To obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 8281 E Evans Rd Suite 103 Scottsdale AZ 85260 The defective unit must be accompanied by a description of t...

Отзывы: