Spencer CROSS Скачать руководство пользователя страница 14

 

Do not place limbs and/or objects between the legs and the frame, in the vicinity of the leg lifting pistons or in general between moving 
parts as this may result in crushing injuries. 

 

If the twist system has been activated, make sure that the wheels are locked again before loading the stretcher into the ambulance as 
this can be risky and difficult with the front wheels unlocked. 

 

Movement  with  four  swivel  wheels  can  be  very  difficult  on  sloping  or  uneven  ground.  Carefully  assess  the  conditions  of  use  before 
unlocking the front wheel pivot.  

 

If the device is used in conjunction with restraint systems such as spine boards and/or vacuum mattresses, make sure that the patient is 
secured  to  the  stretcher  and  the  restraint  system  so  that  the  patient  is  safe  while  the  vehicle  is  moving.  In  case  of  doubt  about  the 
procedures to be used, refer to the operating protocols of your relative 118 service.  

6.1

 

PHYSICAL REQUIREMENTS FOR OPERATORS  

The  device  is  intended  for  professional  use  only.  All  operators  must  be  trained  to  transport  patients  safely  and  efficiently.  Do  not  allow 
untrained persons to help while using the product, as they may cause injury to themselves or others. 
Operators using the device should be physically able to use the device and have good muscle coordination, as well as strong back, arms, and 
legs for lifting and holding and be able to grasp the device firmly with both hands. 

Operators must be able to provide the necessary patient care. 

Users  must  be  able  to  safely  lift  and  handle  the  weight  of  the  stretcher  and  patient  together  and  any  other  equipment  used  with  the 
device. 

For patient loading techniques for particularly heavy patients, for operations on steep terrain or in special and unusual circumstances, the 
presence of multiple operators is recommended (not just 2 as expected in standard conditions). 

The ability of each operator must be assessed before the definition of rescuer roles in use of the stretcher. 

7.

 

RESIDUAL RISK 

The residual risks listed below have been identified solely with reference to the intended use of the device. 

 

Use by untrained personnel may result in injury to the patient, rescuer or third parties. 

 

Inadequate disinfection procedures may lead to risk of cross-infection. 

 

Partial opening of the legs may result in the device falling to the ground. Make sure that the legs are properly locked before any handling 
and that the pistons are fully extended and stable. 

 

If the stretcher is not locked on the fixing system or if it is not correctly positioned, this can result in dangerous movements, especially in 
the event of strong medical vehicle deceleration, which can cause damage to the patient and the operators. Always make sure that the 
locking system is properly engaged. 

 

Failure to observe the warnings for operators can lead to risks of crushing caused by the moving mechanisms. 

 

Accidental  operation  of  the  variable  height  system  may  result  in  the  stretcher  falling,  causing  injury  to  the  patient  and/or  operators. 
Make sure that the unlocking handle is not accidentally activated.  

 

The operators should prepare to fully load the stretcher with the patient and accessories before operating the variable height unlocking 
control. Operating this control without applying sufficient support force will result in the stretcher falling unexpectedly and causing injury 
to the patient or operators. 

 

Failure to read and understand the product instructions may result in injury to the patient and operators. 

8.

 

TECHNICAL DATA AND COMPONENTS 

Note: Spencer Italia S.r.l. reserves the right to make changes to specifications without notice. 

 

CROSS

 CROSSOVER  

 

See Callout Image 

P2

 

 

No. 

Description 

Material 

No. 

Description 

Material 

Trendelenburg control lever (if 

present) 

Steel/PE 

Rear wheel brake 

FE 

Trendelenburg/Fowler control lever 

/(if present) 

Steel 

Sidebar unlocking levers 

Nylon 

Twist control lever 

PE 

Variable height unlocking lever 

Nylon 

Rear leg unlocking handle (green) 

Nylon 

Loading trolley unlocking control 

PU/Steel 

Front leg unlocking handle 

Nylon 

10 

Backrest adjustment unlocking control 

PE/Steel 

 

See Callout Image 

P3

 

 

No. 

Description 

Material 

No. 

Description 

Material 

11 

Sidebars 

Al/Steel/Nylon 

18 

Twist system 

Steel/Nylon 

12 

Feet side patient bed 

PE 

19 

Gas spring 

Steel 

13 

Main frame perimeter/Handle 

Steel 

20 

Front piston 

Steel 

14 

Rear piston 

Steel 

21 

Crossbar for front fixing 

Steel 

15 

Rear leg 

Steel 

22 

Loading trolley wheels 

PU 

Содержание CROSS

Страница 1: ...PENCER ITALIA SRL Via Provinciale n 12 43038 Sala Baganza PR Italy SPENCER ITALIA SRL Via Provinciale n 12 43038 Sala Baganza PR Italy www spencer it support spencer it e mail info spencer it service service spencer it Ph Tel 39 0521 541111 Quality System EN ISO 9001 EN ISO 13485 ...

Страница 2: ...2 P1 P2 P3 P4 P5 ...

Страница 3: ...3 P6 P7 P8 P9 P10 P11 P12 P13 P14 ...

Страница 4: ...4 P15 P16 P17 P18 P19 P20 P21 P22 ...

Страница 5: ...5 P23 P24 P25 P26 P27 P28 P29 P30 P31 P32 SHARP SHARP SL P33 P34 ...

Страница 6: ...6 P35 P36 P37 P38 P39 P40 P41 P42 P43 P44 P45 P46 ...

Страница 7: ...7 P47 P48 P49 P50 P51 P52 P53 P54 P55 P56 P57 ...

Страница 8: ...8 P58 P59 P60 P61 ...

Страница 9: ...PERIODIC OVERHAUL 16 12 4 SPECIAL MAINTENANCE 17 12 5 LIFE SPAN 17 13 TROUBLESHOOTING TABLE 17 14 ACCESSORIES 18 14 1 ACCESSORIES 18 15 SPARE PARTS 18 16 DISPOSAL 19 Notice The information contained in this document is subject to change without notice and is to be intended as a commitment by Spencer Italia S r l subject to change The images are included as examples and may vary slightly from the a...

Страница 10: ...best instructions are the continuous practice of use under the supervision of competent and trained personnel Regardless of your level of experience with similar devices in the past you should carefully read and understand the contents of this manual before installing operating or servicing this product In case of any questions please contact Spencer Italia S r l for the necessary clarifications T...

Страница 11: ...be traced the device must be reconditioned provided only under the responsibility of the manufacturer Regulation 2017 745 EU requires manufacturers and distributors of medical devices to keep track of their location If the device is in a location other than the address to which it was shipped or sold or if it was donated lost stolen exported or destroyed permanently removed from use or if the devi...

Страница 12: ...nts Avoid contact with sharp objects Device installation must be carried out by qualified personnel trained and enabled by Spencer Italia S r l The times and methods of such shall be agreed upon between the customer and our Sales Offices Operating temperature from 10 C to 50 C Storage The product must not be exposed or come into contact with thermal sources of combustion or flammable agents but mu...

Страница 13: ...n any way replace his or her supervision Pay the utmost attention to any obstacles water ice debris etc present on the route as they may cause the operator to lose balance and compromise proper functioning of the device If you cannot clear the way choose an alternative route Condensation water ice and accumulations of dust can affect correct operation of the device making it unpredictable and caus...

Страница 14: ...y result in injury to the patient rescuer or third parties Inadequate disinfection procedures may lead to risk of cross infection Partial opening of the legs may result in the device falling to the ground Make sure that the legs are properly locked before any handling and that the pistons are fully extended and stable If the stretcher is not locked on the fixing system or if it is not correctly po...

Страница 15: ... 19 Front legs Steel 12 Rear lock system Steel Nylon Aluminium 20 Variable height control lever Nylon 13 Rear wheel with bracket PU 21 Loading trolley wheel PU 14 Brake Chrome plated FE 22 Stops for Cross Up 8409 stretcher Steel Nylon 15 Rear leg lifting piston Steel 23 Front wheel unlocking lever TWIST version only Polyethylene 16 Rear legs Steel 24 Stretcher release lever Nylon 17 Front leg lift...

Страница 16: ...nt bed height with trolley at intermediate height mm 760 830 Cross Chair patient bed height with trolley lowered mm 395 Leg and loading trolley wheels mm Ø 200 Load capacity kg 170 250 Crossover Chair Weight kg 32 Available in 10g version Note 1 The patient bed height specifications are measured without mattress Note 2 The double dimensional values in some fields refer to the rear and front of the...

Страница 17: ...ng on whether you wish to increase or reduce the loading height The new position must allow for insertion of both previously removed screws P11 Insert the screws and partially tighten them Carry out the same operation on the plate located on the opposite side of the stretcher P12 Move the loading trolley to its new position Place the loading trolley on the vehicle floor and check that the height i...

Страница 18: ...king handle green When engaged it unlocks the movement of the rear leg allowing it to be closed E Front leg unlocking handle red When engaged it unlocks the movement of the front leg allowing it to be closed F Rear wheel brake When engaged it brakes the rear wheels G Sidebar unlocking levers When engaged at the same time they unlock the sidebar and open it It is not necessary to operate any contro...

Страница 19: ...om the ground during loading unloading or when the loading trolley is still on the vehicle to allow the front leg to open safely Failure to take the above measure will preclude safe use of the device resulting in risk of damage to the patient operators and the device itself 11 2 Parking brakes Image P20 To engage the parking brakes simply press on the strips on the rear wheel brackets with your fo...

Страница 20: ...g the stretcher from the trolley Cross Up and Cross Chair Images P27 and P28 Brake the trolley with the parking brakes Engage the corresponding control lever and pull out the stretcher sliding it about ten centimetres Complete the operation by lifting the stretcher from the trolley This operation requires at least two operators one on the foot side of the stretcher to operate the controls one on t...

Страница 21: ...n To reach this position lift the end of the board by grasping the two rings at its end Ensure that the set screw is properly seated in its socket before releasing the rings To change from the Trendelenburg position to the standard position lift the patient bed slightly by grasping the end of the frame check that the set screw is out of its socket and then support the frame as it goes back down to...

Страница 22: ...able part of the frame as it moves towards the ground Caution Hazard of crushing fingers Make sure that your hands or those of other operators or other objects are not in the area where the mobile frame joins the fixed frame highlighted in the figure with the warning symbol Return the rear telescopic handles to Position 1 The patient can only be lifted after checking that these are fully inserted ...

Страница 23: ... not equipped with a pre tensioner It is therefore necessary to manually adjust them after fastening them tensioning the straps and bringing the re winding system to the end of the stroke Incorrect adjustment makes the device unsafe and ineffective 12 CLEANING AND MAINTENANCE Spencer Italia S r l declines all responsibility for any direct or indirect damage which is the consequence of improper use...

Страница 24: ...e device The operator must wear suitable personal protective equipment such as gloves goggles etc during all checking maintenance and cleaning operations Checks to be carried out before and after each use and at deadline indicated above are as follows General functionality of the device Cleanliness of the device remember that the failure of cleaning may cause the risk of cross infections Correct t...

Страница 25: ...e the device from service and contact the service centre The stretcher is not correctly attached to the fixing system Wear or damage of the components that constitute the locking mechanisms Immediately remove the device from service and contact the service centre The fifth wheel has not been properly inserted in the fixing system Position the stretcher properly and check that the fifth wheel enter...

Страница 26: ...702C Hook R MAX B certified 10G IF01047C TRACK 4 30 TELESCOPIC IV HOLDER EN90003C END T 10G INSTRUMENTS TABLE CB09028C TANKER FIXING SUPPORT FOR SAFEBAR CB09025C TANKER YELLOW OXY TANK HOLDER FOR STRETCHER SIDERAIL FIXING ST00491A STX 90 TELESCOPIC HEADREST FOR STRETCHERS CR90010B Adapter for loading trolley wheels CR90011B S MAX HUX LOADING TROLLEY EXTENDER CR90012C LOADING TROLLEY ADAPTER FOR S ...

Страница 27: ...ing system ST00498B DNA Strap with re winding system 16 DISPOSAL When devices and their accessories are no longer suitable for use they can be disposed of as normal municipal solid waste if they have not been contaminated by special agents Otherwise follow the regulations in force regarding disposal ...

Отзывы: