Do not place limbs and/or objects between the legs and the frame, in the vicinity of the leg lifting pistons or in general between moving
parts as this may result in crushing injuries.
•
If the twist system has been activated, make sure that the wheels are locked again before loading the stretcher into the ambulance as
this can be risky and difficult with the front wheels unlocked.
•
Movement with four swivel wheels can be very difficult on sloping or uneven ground. Carefully assess the conditions of use before
unlocking the front wheel pivot.
•
If the device is used in conjunction with restraint systems such as spine boards and/or vacuum mattresses, make sure that the patient is
secured to the stretcher and the restraint system so that the patient is safe while the vehicle is moving. In case of doubt about the
procedures to be used, refer to the operating protocols of your relative 118 service.
6.1
PHYSICAL REQUIREMENTS FOR OPERATORS
The device is intended for professional use only. All operators must be trained to transport patients safely and efficiently. Do not allow
untrained persons to help while using the product, as they may cause injury to themselves or others.
Operators using the device should be physically able to use the device and have good muscle coordination, as well as strong back, arms, and
legs for lifting and holding and be able to grasp the device firmly with both hands.
Operators must be able to provide the necessary patient care.
Users must be able to safely lift and handle the weight of the stretcher and patient together and any other equipment used with the
device.
For patient loading techniques for particularly heavy patients, for operations on steep terrain or in special and unusual circumstances, the
presence of multiple operators is recommended (not just 2 as expected in standard conditions).
The ability of each operator must be assessed before the definition of rescuer roles in use of the stretcher.
7.
RESIDUAL RISK
The residual risks listed below have been identified solely with reference to the intended use of the device.
•
Use by untrained personnel may result in injury to the patient, rescuer or third parties.
•
Inadequate disinfection procedures may lead to risk of cross-infection.
•
Partial opening of the legs may result in the device falling to the ground. Make sure that the legs are properly locked before any handling
and that the pistons are fully extended and stable.
•
If the stretcher is not locked on the fixing system or if it is not correctly positioned, this can result in dangerous movements, especially in
the event of strong medical vehicle deceleration, which can cause damage to the patient and the operators. Always make sure that the
locking system is properly engaged.
•
Failure to observe the warnings for operators can lead to risks of crushing caused by the moving mechanisms.
•
Accidental operation of the variable height system may result in the stretcher falling, causing injury to the patient and/or operators.
Make sure that the unlocking handle is not accidentally activated.
•
The operators should prepare to fully load the stretcher with the patient and accessories before operating the variable height unlocking
control. Operating this control without applying sufficient support force will result in the stretcher falling unexpectedly and causing injury
to the patient or operators.
•
Failure to read and understand the product instructions may result in injury to the patient and operators.
8.
TECHNICAL DATA AND COMPONENTS
Note: Spencer Italia S.r.l. reserves the right to make changes to specifications without notice.
CROSS
–
CROSSOVER
See Callout Image
P2
No.
Description
Material
No.
Description
Material
1
Trendelenburg control lever (if
present)
Steel/PE
6
Rear wheel brake
FE
2
Trendelenburg/Fowler control lever
/(if present)
Steel
7
Sidebar unlocking levers
Nylon
3
Twist control lever
PE
8
Variable height unlocking lever
Nylon
4
Rear leg unlocking handle (green)
Nylon
9
Loading trolley unlocking control
PU/Steel
5
Front leg unlocking handle
Nylon
10
Backrest adjustment unlocking control
PE/Steel
See Callout Image
P3
No.
Description
Material
No.
Description
Material
11
Sidebars
Al/Steel/Nylon
18
Twist system
Steel/Nylon
12
Feet side patient bed
PE
19
Gas spring
Steel
13
Main frame perimeter/Handle
Steel
20
Front piston
Steel
14
Rear piston
Steel
21
Crossbar for front fixing
Steel
15
Rear leg
Steel
22
Loading trolley wheels
PU
Содержание CROSS
Страница 2: ...2 P1 P2 P3 P4 P5 ...
Страница 3: ...3 P6 P7 P8 P9 P10 P11 P12 P13 P14 ...
Страница 4: ...4 P15 P16 P17 P18 P19 P20 P21 P22 ...
Страница 5: ...5 P23 P24 P25 P26 P27 P28 P29 P30 P31 P32 SHARP SHARP SL P33 P34 ...
Страница 6: ...6 P35 P36 P37 P38 P39 P40 P41 P42 P43 P44 P45 P46 ...
Страница 7: ...7 P47 P48 P49 P50 P51 P52 P53 P54 P55 P56 P57 ...
Страница 8: ...8 P58 P59 P60 P61 ...