Possible Cause

VI. Troubleshooting Guide - Vacuum Producer

PROBLEM

INSUFFICIENT

AIR THROUGH

SYSTEM

MACHINE

NOISY

Corrective Action

Change motor leads to correct rotation.
Following instructions on pages 7-8, disassemble machine and

reassemble correctly.
Increase tubing size or install machine providing higher vacuum.
Restrict number of simultaneous operators or upgrade to larger

Industravac unit.
Use only Spencer tools, do not use open end hoses.

Refer to motor manufacturer's instructions, check voltage supply

and connections.
Disassemble, clean and inspect all parts, check filter bags for holes.
Replace impellers.
Refer to air gate instructions on page 6 and readjust.

Install larger Industravac unit to handle system requirements.
Eliminate all leakage; see separator troubleshooting section.

Remove drain plug and let excess grease drain out.
Grease per instructions of motor manufacturer.
Replace bearing.
Replace bearing.

Reassemble per instructions on pages 7-8, tighten impellers.

Bleed air at low flow to reduce heat.
Replace impellers.
Repair or replace deflectors.
Too much material passing through separator. Replace

impellers and/or deflectors. Check filter bags for holes. Check to

be sure filter bag material is correct for debris collected.
Increase air flow to stop surge condition.

Rebalance and/or clean machine, see further comments under

Machine Vibrating.
Reassemble and carefully realign shaft and motor.
Disassemble machine, inspect and clean. Check filter bags for

holes to prevent further clogging.

Check motor manufacturer's instructions, check voltage supply

and connections.
Check motor manufacturer's instructions, check voltage supply

and connections.
See External Machine Malfunction.
Rebuild motor properly and correct the end play.
Tighten, repair or replace. (Check with motor manufacturer.)
Separate power supply, correct frequency.

Indication: low vacuum as determined by gauge measurement

• Incorrect rotation.
• Incorrect reassembly of machine after customer

repairs.

• Tubing too small, causing excessive friction loss.
• Too many operators using system at once.

• Too much air entering system due to improper

tools or open end hoses being used.

• Machine running slow due to low motor voltage.

• Machine air passages clogged with material.
• Impellers worn due to abrasion or vibration.
• Air gate (blast gate) closed.

• System requirements incorrectly calculated.
• Too much leakage and/or openings.

• Too much grease; motor bearings hot.
• Too little grease; motor bearings dry.
• Bearing failure.
• Bearing retainers worn.

• Impellers hitting after field reassembly and/or

slipping on shaft due to heat.

• Impellers coming apart due to age.
• Deflectors coming apart due to age.
• Impellers and/or deflectors coming apart due to

wear from dirty air.

• Machine operating in surge or unbalanced flow

range.

• Machine unbalanced, running rough.

• Motor not aligned in casing, causing impellers to hit.
• Foreign material in machine.

Indication: motor malfunction

• Abnormal hum or whine.

• Wrong voltage (high voltage will burn out motor

and cause noticeable noise).

• Bearing noise.
• Motor rebuilt improperly, thrust taken on wrong end.
• Loose part in motor.
• Low frequency.

Indication: external machine malfunction–bearing whining or growling

Indication: machine design capacity too small for the system

Indication: internal machine malfunction

Содержание A

Страница 1: ...tructions detailed here will help you realize its full potential of efficient service and extended lifespan Damage resulting from failure to follow correct procedures will void the warranty Mobile Models Series A pictured Stationary Models Series B pictured Spencer Industravac Self Contained Vacuum Cleaning Systems Series A B C D V Serial No Model No Filter Bags The Spencer Turbine Company Windsor...

Страница 2: ...rs and ground wire electrical cable ready for your addition of a male plug and connection to a suitable power supply Refer to the machine nameplate for specific electrical information Stationary Model The stationary Industravac model is intended for permanent installation in one location where for example it may be connected to a tubing network to form a central vacuum cleaning system Since the mot...

Страница 3: ...rly protected from precipitation Mobile Model The mobile Industravac unit is designed for use on flat dry level surfaces As a safety precaution the wheels should be blocked to prevent accidental movement Typical Industravac Assembly Filter Bag Buckle External Bag Shaker Access Door Inverted Filter Bags Adjustable Door Latches Vacuum Tube Inlet Target Plate Patent No 4 874 410 Optional Equilizing Li...

Страница 4: ...ing sure it seals tightly against the gasket Inspect both separator inlet ports to be sure they are clear If optional dirt can liners will be used install one liner in the dirt can and make sure the equalizing line is in place properly connected to the separator and dirt can CAUTION The dirt can liner must not be used without the equalizing line the liner will be sucked out of the can up against t...

Страница 5: ... O D INLET INLET VALVE MANUAL BAG SHAKER INLET VALVE INLET VALVE INLET VALVE STARTER HANDLE 6 O D EXHAUST OUTLET INLET VALVE MANUAL BAG SHAKER INLET 6 O D EXHAUST OUTLET 41 3 cu ft DIRT CAN 5 O D INLET 41 3 cu ft DIRT CAN EXHAUST DIFFUSER INLET VALVE STARTER HANDLE MANUAL BAG SHAKER INLET VALVE INLET VALVE Stationary Model Mobile Model Stationary Model Mobile Model ...

Страница 6: ...BAG SHAKER 21 4 cu ft DIRT CAN 21 4 cu ft DIRT CAN Stationary Model Stationary Model EXHAUST DIFFUSER STARTER HANDLE 41 3 cu ft DIRT CAN 71 2 cu ft DIRT CAN INLET VALVE INLET VALVE DOWNBLAST EXHAUST LIFTING HOOK LIFTING HOOK LIFTING HOOK 8 O D EXHAUST OUTLET 5 O D INLET MANUAL BAG SHAKER 6 O D INLET INLET MANUAL BAG SHAKER Patent No 5 087 274 INLET VALVE ...

Страница 7: ...ting open the air gate until the amperage reach es but does not exceed the full rated motor capacity The air gate should then be fixed to prevent opening beyond this point 3 For units equipped with Electronic Modulating Bleed Control Follow adjustment instructions in the separate data sheet accompanying the EMBC 4 Check the tubing system and vacuum equipment for leaks At the separator check the ac...

Страница 8: ...Representative describing the situation in detail before attempting repairs or disassembly The Industravac vacuum producer has an overhung type construction with multiple impellers mounted directly on the motor shaft The motor bearings support the shaft and impeller assembly Six impellers and five deflectors are shown in the diagram above of a typical vacuum producer the actual number of each will v...

Страница 9: ...lf locating guide positions the can correctly Lower the bail arm lifting the can into position and sealing it against the rubber gasket Changing Door and Dirt Can Gaskets 1 Peel off old gasket 2 Clean old adhesive off gasket seat 3 Check replacement gasket for fit trim if necessary 4 Coat gasket and seat with rubber cement apply gasket 5 Check for airtight seal after cement is dry Maintaining the E...

Страница 10: ...g the Target Plate The target plate Patent No 4 874 410 at the bottom of the separator is able to absorb a great deal of impact and abrasion damage as it diverts solid litter into the dirt can Because it will eventually wear out provisions have been made for easy replacement 1 Lower the dirt can and wheel it out of the way 2 Swing the target plate to a horizontal position and release it from its s...

Страница 11: ...structions check voltage supply and connections Check motor manufacturer s instructions check voltage supply and connections See External Machine Malfunction Rebuild motor properly and correct the end play Tighten repair or replace Check with motor manufacturer Separate power supply correct frequency Indication low vacuum as determined by gauge measurement Incorrect rotation Incorrect reassembly o...

Страница 12: ...cycle Repair or replace motor Upgrade to larger Industravac unit or reduce amount of air in vacuum producer Verify amperage of motor Set air gate Check components and tubing system for leaks Consult power company for correction Material buildup on impellers Shaft bent 001 max runout per 10 of length Bearing failure Faulty replacement motor installed Motor imbalance Machine reassembled incorrectly ...

Страница 13: ...13 Filter Bag Part No Filter Bag Maintenance Record Date Filter Bag Material Date Changed ...

Страница 14: ...14 Vacuum Accessories Record Hoses Tools Valves Part No Description ...

Страница 15: ...application from general floor cleaning to car upholstery vacuuming and specialized bulk material handling Bulletin No 241 Tubing Fittings and System Components Catalog Bulletin 600 covers every variety of components for Industravac based central vacuum cleaning systems metal tubing elbows branches couplings reducers adapters shrink sleeves air gates check valves everything you need for specialized...

Страница 16: ...ation isolators and other system components Comprehensive engineering and other customer support services The industryʼs largest complement of technical specialists in air and gas handling technology Worldwide parts and service organization Application research and testing facility Worldwide organization of sales representatives and distributors offering Product selection installation and operatio...

Отзывы: