SAFETY 

 
 
 
 

 

DANGER 

HIGH VOLTAGE 

RISK OF ELECTROCUTION  

 

Observe extreme caution when working with this equipment 

 

 

 

High voltage power supplies must always be connected to 
protective earth 

 

 

 

Do not touch connections unless equipment is turned off and 
the capacitance of both the load and power supply are 
grounded 

 

 

 

Allow adequate time for discharge of internal capacitance of 
the power supply 

 

 

 

Do not ground yourself or work under wet or damp 
conditions 

 

 

Servicing Safety 

 

 

 

Maintenance may require removing the Instrument cover with 
the power on 

 

 

 

Servicing should only be done by qualified personnel aware 
of the hazards 

 

 

 

If in doubt, return to supplier for servicing 

 

Содержание XMPF10N5/24

Страница 1: ... INSTALLATION INSTRUCTIONS Document Number 81234 4 Issue A Date 23 01 18 Issuing Authority I 5650 Checked Approved Tel 44 0 1798 873986 Fax 44 0 1798 872479 E mail hvsales spellmanhv co uk Broomers Park Broomers Hill Lane Pulborough W Sussex RH20 2RY ...

Страница 2: ...tions unless equipment is turned off and the capacitance of both the load and power supply are grounded Allow adequate time for discharge of internal capacitance of the power supply Do not ground yourself or work under wet or damp conditions Servicing Safety Maintenance may require removing the Instrument cover with the power on Servicing should only be done by qualified personnel aware of the haz...

Страница 3: ...and the conditions of this manual must be complied with to maintain safety Operating the unit in a manner not specified in this manual may impair the protection against electric shock provided by the unit The unit is contained in an earthed case the system protective earth shall be provided to the chassis The case of the unit shall be properly bonded to the main protective earth termination in the...

Страница 4: ...arranty 3 2 Mechanical Installation The unit should only be used in a Pollution Degree 2 Installation Category II environment The input and output connectors are not intended for field connections and should only be connected to internal wiring in the end product The unit is intended for use as a component and no surface of the unit should be accessible in the end product 3 3 Electrical Installati...

Страница 5: ...de voltage program input 0 10V input 9 Cathode voltage monitor 0 10V output 10 Emission current monitor 0 10V output 11 Filament current monitor 0 10V output 12 Emission current program input 0 10V input 13 Emission current program output 0 10V from internal pre set 14 Signal ground 15 Pre set maximum filament current set value 4 2 Output The HV output is a flying lead consisting of 2 Reynolds 18k...

Отзывы: