205B Series User’s Manual 

118124-001-Rev.A 

THIS 

UNIT 

CONTROLS 

HAZARDOUS 

VOLTAGES.    DO  NOT  APPLY  INPUT  POWER 

UNLESS 

ADEQUATE 

GROUNDING 

IS 

PROVIDED TO THE POWER SUPPLY AND THE 

HIGH  VOLTAGE  OUTPUT  HAS  BEEN 

PROPERLY CONNECTED. 

THE  DATA  CONTAINED  IN  THIS  MANUAL  IS 

SUBJECT  TO  CHANGE  WITHOUT  NOTICE.  

WRITTEN PERMISSION FROM SPELLMAN HIGH 

VOLTAGE  IS  REQUIRED  PRIOR  TO  THE 

REPRODUCTION  OF  ANY  TECHNICAL  DATA 

CONTAINED IN THIS MANUAL. 

SECTION I:  GENERAL DESCRIPTION 

1.0 

SCOPE OF MANUAL 

This  manual  is  provided  to  assist  the  user  in  the 

installation  and  operation  of  the  Spellman  Series 

205B rack-mountable high voltage power supplies.  

Statements apply to all models in the Series unless 

reference  is  made  to  specific  models.    For  the 

protection  of  personnel  and  equipment,  it  is 

essential that this manual be thoroughly read prior 

to the installation and application of power. 

1.1  

PURPOSE OF EQUIPMENT 

The  series  205B  is  a  family  of  regulated  precision 

regulated,  locally  and  remotely  variable  high 

voltage  power  supplies.    They  offer  exceptional 

performance in such critical applications as nuclear 

and  electro-optical  instrumentation,  medical 

imaging  and  capillary  zone  electrophoresis  and 

precision CRT displays. 

1.2 

DESCRIPTION 

The units are fully enclosed and designed to mount 

in  a  standard  19”  rack.    A  wide  range  of  stable 

output voltages from 1kV up to 50 kV is available.  

The  output  voltage  is  set  either  by  front  panel 

controls  or  remote  analog  voltage  or  resistance 

programming.    Remote  analog  monitoring  is 

provided on all models. 

Output  polarity  reversal  is  achieved  by  turning  a 

polarity  switch  on  the  rear  panel  of  1kV,  3kV  and 

5kV  models.   The  10kV and  higher output  models 

have an internal polarity reversing assembly that is 

easily accessible in the field.  NOTE: in either case, 

polarity  reversal  MUST  ONLY  BE  DONE  WHEN 

THE HIGH VOLTAGE IS OFF. 

The Series 205B units contain a DC power supply 

that converts the AC line power to a low voltage DC 

and a DC-to-DC converter that generates the high 

DC  voltage.    Low  voltage  electronics  solid-state 

analog circuits are placed on plug–in printed circuit 

boards.    The  high  voltage  assembly  is  fully 

encapsulated  in  silicone  rubber  for  reliable,  arc- 

free, stable operation. 

SECTION II:  OPERATION 

CAUTION!  THIS UNIT CAN STORE 

HAZARDOUS VOLTAGE.  COMPLETELY 

DISCHARGE HIGH VOLTAGE AT REAR PANEL 

GROUND TERMINAL BEFORE ATTEMPTING 

REMOVAL OF THE HIGH VOLTAGE CABLE 

2.1 

INSTALLATION: 

The  205B  Series  high  voltage  power  supplies 

mount in a standard 19” rack. 

2.2 

INPUT POWER 

The  input  AC  line  voltage  required  is 

115V/230VAC,  ±10%,  50-400Hz,  single  phase.  

The  LINE  VOLTAGE  selector  switch  on  the  rear 

panel  MUST  BE  SET  for  either  115VAC  or 

230VAC BEFORE application of input power. 

2.3 

VOLTAGE CONTROL 

The 205B Series power supply has two modes of 

controlling the high voltage outputs available to the 

user.    Set  the  PROGRAM  CONTROL  switch 

(S101) on the rear panel to LOCAL for front panel 

control.  For remote analog control, set the switch 

to  the  REMOTE  ANALOG  position.    The  high 

voltage output can then be remotely programmed 

either from an external voltage source or by using 

an  external  potentiometer.    When  S101  is  in  the 

REMOTE  ANALOG  position,  the  front  panel 

controls  will  have  no  effect  on  the  output  voltage 

setting. 

At all times, regardless of the position of the rear 

panel PROGRAM CONTROL switch, the user may 

enable  or  disable  the  high  voltage  output  by 

switching  the  HV  ENABLE  switch  on  the  front 

panel.    In  addition,  the  voltage  and  current 

monitors are always active.  Thus, even when the 

PROGRAM CONTROL switch is set to REMOTE 

ANALOG control position, the front panel and the 

remote analog monitors continue to make voltage 

and current readings available. 

2.4 

POLARITY REVERSAL 

The  front  panel  LED  display  will  indicate  which 

polarity the unit is set for.  The display illuminates 

even if there is no high voltage output. 

CAUTION  –  LINE  INPUT  POWER  MUST  BE 

TURNED  OFF  AND  THE  HIGH  VOLTAGE 

SHOULD  BE  DISCHARGED  FULLY  BEFORE 

PROCEEDING TO REVERSE THE POLARITY. 

Содержание 205B-01R

Страница 1: ...nstruction Manual Rack Mount High Voltage Power Supply SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION One Commerce Park Valhalla New York 10595 1 914 686 3600 FAX 1 914 686 2870 E mail sales spellmanhv com Website http www spellmanhv com 205B SERIES ...

Страница 2: ...ction table Temperature Coefficient 50ppm C Stability 0 01 hour 0 02 per 8 hours after a 1 2 hour warm up Accuracy Current Monitor 0 5 of reading 0 25 of maximum Remote Programming 0 1 of setting 0 1 of maximum Voltage Monitor 0 1 of reading 0 1 of maximum Front Panel Meter Voltage 0 1 of setting 0 1 of maximum Current 0 25 of setting 0 25 of maximum Front Panel Control 0 25 of setting 0 05 of max...

Страница 3: ...488 sold separately 9 Polarity Indicator Open collector 30V 25mA positive ON PAGE 2 OF 2 MODEL SELECTION TABLE 205B Series Voltage Current Ripple 205B 01R 0 to 1kV 0 to 30mA 10mV 205B 03R 0 to 3kV 0 to 10mA 30mV 205B 05R 0 to 5kV 0 to 5mA 50mV 205B 10R 0 to 10kV 0 to 2 5mA 100mV 205B 20R 0 to 20kV 0 to 1mA 300mV 205B 30R 0 to 30kV 0 to 0 5mA 400mV 205B 50R 0 to 50kV 0 to 0 3mA 2 volts DIMENSIONS i...

Страница 4: ... aware of the electrical hazards WARNING note in the text call attention to hazards in operation of these units that could lead to possible injury or death CAUTION notes in the text indicate procedures to be followed to avoid possible damage to equipment Copyright 2000 Spellman High Voltage Electronics Corporation All Rights Reserved This information contained in this publication is derived in par...

Страница 5: ...spannungsnetzteiles benötigen ca 5 Minuten um sich zu entladen Erden Sie sich nicht und arbeiten Sie nicht in feuchter oder nasser Umgebung Notwendige Reparaturen können es erforderlich machen den Gehäusedeckel während des Betriebes zu entfernen Reparaturen dürfen nur von qualifiziertem eingewiesenem Personal ausgeführt werden WARNING im folgenden Text weist auf gefährliche Operationen hin die zu ...

Страница 6: ...de l alimentation Ne vous mettez pas à la masse ou ne travaillez pas sous conditions mouillées ou humides La maintenance peut nécessiter l enlèvement du couvercle lorsque l alimentation est encore allumée Les réparations doivent être effectuées par une personne qualifiée et connaissant les risques électriques Dans le manuel les notes marquées WARNING attire l attention sur les risques lors de la m...

Страница 7: ...carica della capacità interna dell alimentatore ad alta tensione Non mettere a terra il proprio corpo oppure operare in ambienti bagnati o saturi d umidità SICUREZZA NELLA MANUTENZIONE Manutenzione potrebbe essere richiesta rimuovendo la copertura con apparecchio acceso La manutenzione deve essere svolta da personale qualificato coscio dei rischi elettrici Attenzione alle AVVERTENZE contenute nel ...

Страница 8: ...er 2 2 3 Voltage Control 2 2 4 Polarity Reversal 2 2 4 1 Polarity Reversal 1kV to 5kV Output Models 3 2 4 2 Polarity Reversal 10kV to 50kV Output Models 3 III LOCAL OPERATION 3 1 Front Panel Controls 3 3 2 Program Control Switch 3 3 3 Local Operation 3 IV REMOTE ANALOG OPERATION 4 1 Program Control Switch 3 4 2 Remote Control 3 4 3 Analog Monitoring Signals 3 4 V MAINTENANCE 5 1 General 4 ...

Страница 9: ...ly that converts the AC line power to a low voltage DC and a DC to DC converter that generates the high DC voltage Low voltage electronics solid state analog circuits are placed on plug in printed circuit boards The high voltage assembly is fully encapsulated in silicone rubber for reliable arc free stable operation SECTION II OPERATION CAUTION THIS UNIT CAN STORE HAZARDOUS VOLTAGE COMPLETELY DISC...

Страница 10: ...the units rear panel PROGRAM CONTROL switch S101 is in the LOCAL position However if the unit receives a voltage programming command while S101 is in the Remote Analog position the switching of S101 to its LOCAL position afterwards will then cause the value of that programming command to take effect 3 3 LOCAL OPERATION The local mode of the 205B Series provides all of the control and monitoring fu...

Страница 11: ... collector with respect to digital ground indicating output high voltage polarity NPN saturation denotes positive polarity logic 0 NPN cut off denotes negative polarity logic 1 SECTION V MAINTENANCE 5 1 GENERAL Your 205B Series high voltage power supply is designed for reliable trouble free operation If any questions should arise contact Spellman s Customer Service Department for assistance or ret...

Страница 12: ...lleged breach of this warranty No modification amendment supplement addition or other variation of this warranty will be binding unless it is set forth in a written instrument signed by an authorized officer of Spellman Factory Service Procedures For an authorization to ship contact Spellman s Customer Service Department Please state the model and serial numbers which are on the plate on the rear ...

Отзывы: