16
Service manual
MicroStar B
rev06
MicroStar B
09
09
09
09
09
Internal adjustement
Solder bridges
Adjustement zone
Internal adjustement
1.12
If changes need to made to the internal drive setting powering, please wait at least 40
seconds after the power has been removed and the OK LED is off.
All of the personalizations are located inside of the DRIVE. To gain access to the adjustment
pads and the Solder bridges, unscrew and remove the cover. (See figure above)
Solder point standard configuration
Solder bridges standard position are setting by
factory for:
- Encoder feedback
- Ramp time disabled
- Standard Dynamic constant
S1: Open
S2: Closed
S3: Open
S4: Closed
S5: Closed
S6: Open
S7: Open
S8: Closed
S9: Open
S10: Open
S11: Closed