1. Pressure Gauge
2. Water Level Low Indicator
3. Steam Control Knob
4. Hose Connector
5. Steam Ready Indicator
6. Power/Boiler Switch
7. Water Tank Cap (Not Shown)
SC-VSC-7000
Setup and Operation
Setup
1. Remove the SC-VSC-7000 unit from the packaging.
2. Inspect the unit and all accessories for damage and missing parts. If anything is wrong, call
SpeedClean immediately (1-888-700-3540).
Operation
1. Fill the water tank until full.
2. Plug in the SC-VSC-7000 unit and press the power/boiler switch into the ‘ON’ position.
3. When the unit starts, continue filling the water tank until the pump stops and the boiler is
full. The pump will continue to stay on until the boiler water level is full (approximately 0.66
Gallons/2.5L).
4. Plug in the 3 meter steam hose into the hose connector port.
5. Once the unit reaches 2 BAR (29 PSI) on the pressure gauge, press the trigger on the steam
hose to prime the unit. After that, continue to allow the boiler to heat up until the green
steam ready indicator light turns on.
6. Once the light is on (about 4.5 BAR or 65 PSI), the unit is ready to use.
NOTE:
This unit is
not made for continuous use. There will be more condensation the longer the trigger is
continuously squeezed.
7. After use, switch the SC-VSC-7000 unit off, and then wait for the unit to cool and
depressurize before putting away.