In mobile home installations, dryer exhaust duct 

must be secured to mobile home structure.

Dryer exhaust duct MUST NOT terminate under 

mobile home.

Dryer exhausts 220 cfm (measured at back of 

dryer).

Static pressure in exhaust duct should not be 

greater than .6 inches water column (1.5 cm), 

measured with manometer placed on exhaust 

duct two feet (61 cm) from dryer (check with 

dryer running and no load).

Exhausting dryer in hard-to-reach locations can 

be done by installing 521P3 Flexible Metal Vent 

Kit (available as optional equipment at extra 

cost).

Failure to exhaust dryer properly will void 
warranty.

NOTE: Venting materials are not supplied with the 
dryer (obtain locally).

Exhaust Direction

The dryer can be exhausted to the outdoors through the 

back, left, right or bottom of the dryer. 

EXCEPTION: 

Gas dryers cannot be vented out the left side 
because of the burner housing.

Dryer is shipped from factory ready for rear exhaust.
Exhausting the dryer through sides or bottom can be 

accomplished by installing a Directional Exhaust Kit, 

528P3, available as optional equipment at extra cost. 

Exhaust System

For best drying results, recommended maximum 

length of exhaust system is shown in 

Table 1

.

To prevent backdraft when dryer is not in operation, 

outer end of exhaust pipe must have a weather hood 

with hinged dampers (obtain locally).

NOTE:  Weather hood should be installed at least 
12 inches (30.5 cm) above the ground. Larger 
clearances may be necessary for installations where 
heavy snowfall can occur.

Table 1 

Number of 

90° Elbows

Weather Hood Type

Recommended

Use Only for Short Run installations

Maximum length of 4 in. (10.2 cm) diameter rigid metal duct.

0

65 feet (19.8 m)

55 feet (16.8 m)

1

55 feet (16.8 m)

47 feet (14.3 m)

2

47 feet (14.3 m)

41 feet (12.5 m)

3

36 feet (11.0 m)

30 feet (9.1 m)

4

28 feet (8.5 m)

22 feet (6.7 m)

Maximum length of 4 in. (10.2 cm) diameter flexible metal duct.

0

45 feet (13.7 m)

35 feet (10.7 m)

1

35 feet (10.7 m)

27 feet (8.2 m)

2

30 feet (9.1 m)

21 feet (6.4 m)

3

25 feet (7.6 m)

17 feet (5.2 m)

4

20 feet (6.1 m)

15 feet (4.5 m)

NOTE: Deduct 6 feet (1.8 m) for each additional elbow.

4 in.

(10.2 cm)

4 in.

(10.2 cm)

D673I

D802I

2-1/2 in.

(6.35 cm)

Содержание KES18AWF

Страница 1: ...chine changes ownership this manual must accompany machine www speedqueen com Installation Instructions for Stacked Dryers Dimensions 3 Before You Start 4 Installing the Dryer 5 Installer Checklist Ba...

Страница 2: ...use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach y...

Страница 3: ...0 in 10 2 cm 26 9 in 68 3 cm 0 4 in 1 1 cm 15 4 in 39 1 cm 15 44 in 39 2 cm 37 44 in 95 1 cm ELECTRIC DRYERS DRY2213N With leveling legs turned into base 1 3 8 in NPT Gas Connection DRY2213N 5 25 in 1...

Страница 4: ...Instructions User s Guide Product Registration Card Warranty Bond Three screws electric dryers only Refer to Connecting Power Cord sections in Step 4 of Installation DRY2023N 1 Safety Glasses 2 Power...

Страница 5: ...here it will be exposed to water and or weather The dryers needs sufficient clearance and an adequate air supply for proper operation and ventilation and for easier installation and servicing Minimum...

Страница 6: ...ts on all duct joints Ductwork that runs through unheated areas must be insulated to help reduce condensation and lint build up on pipe walls DRY2059N 1 Dryer Base 2 Level 3 Leveling Leg 1 2 3 To redu...

Страница 7: ...usting the dryer through sides or bottom can be accomplished by installing a Directional Exhaust Kit 528P3 available as optional equipment at extra cost Exhaust System For best drying results recommen...

Страница 8: ...led as shown for checking inlet pressure Refer to Figure 5 To reduce the risk of gas leaks fire or explosion The dryer must be connected to the type of gas as shown on nameplate located in the door re...

Страница 9: ...dryer has its own terminal block that must be connected to a separate branch 60 Hertz single phase circuit AC alternating current circuit fused at 30 Amperes the circuit must be fused on both sides of...

Страница 10: ...r Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conform to local codes and in...

Страница 11: ...ord into an outlet Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover and screw Connecting Po...

Страница 12: ...the white wire loop the free eyelet end of the ground wire removed in Step 3 and attach along with the white wire to the neutral center terminal on the terminal block 7 Tighten all screws firmly IMPOR...

Страница 13: ...and gas dryer on the same circuit Use separetely fused 15 amp circuits The dryer is designed to be operated on a separate branch polarized three wire effectively grounded 120 Volt 60 Hertz AC alternat...

Страница 14: ...ck Steps 1 6 Refer to Installer Checklist on the back cover of this manual and make sure that dryer is installed correctly Step 8 Check Heat Source Electric Dryers Close the loading door and start the...

Страница 15: ...he air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame indicates too much air Adjust the air shutter as follows 1 Loosen th...

Страница 16: ...59I D255I 2 DRY2010N DRY2010N Connect Dryer Exhaust System CHECK 3 GAS ONLY D258I CHECK Connect Gas Supply Pipe Hoses Check for Gas Leaks 4 D699I W315IE0A ELECTRIC ONLY Connect Electrical Cord CHECK 5...

Отзывы: