20
RRSHA Series Hot Air Blower User Manual ENM-3600-00
2.1.6
Attaching the flexible connecting
duct
1.
Position a flange gasket between the
open end of the track duct and the
flexible connecting duct.
2.
Using eight 1/4”-20 stainless bolts as
shown attach the track duct to the
flexible connecting duct.
Fig. 347
Track Duct to Flexible
Connecting Duct Assembly
3.
Using eight 1/4”-20 stainless bolts
as shown above, connect the other
end of the flexible connecting duct
to the main housing unit at the
matching flanged end.
Fig. 358
Flexible Connecting Duct to
Main Housing Unit Assembly
4.
Check for lack of continuity where the
flexible connecting duct connects to
both the track duck and main housing
unit.
Wiring the main housing unit
2.2.1 Wiring the Circuit Panel
1.
Disable the power coming from the
main power source.
2.
As part of procedure
2.1.2 Routing
power to the main housing unit
, a
hole for the cable from the power
source should have been drilled at
the bottom of the control box, and
the cable should have been routed
through that hole. Verify steps 2 and
3 of procedure 2.1.2 have been
completed, and perform these steps if
they have not.
3.
Connect the cable from the main
power source to the L1, L2, and L3
power distribution blocks.
4.
Enable the power coming from the
main power source.
2.2.2 Verifying the blower fan rotation
After attaching the incoming power cable to
the L1, L2, and L3 power distribution blocks,
verify the blower fan rotation. The blower fan
must rotate counter-clockwise when viewed
facing the inlet grill side of the switch heater.
WARNING:
!
The main circuit breaker feed to
the electrical connections in the
main housing unit must be locked
out and/or tagged out to protect
employees against accidental or
inadvertent operation during any
servicing or maintenance activity.
Lockout is the best and preferred
method of isolating machines or
equipment from energy sources
prior to servicing any component
within the main housing unit. The
lockout/tagout procedure must
comply with employee safety rules
as defined by local corporate
regulation.
Содержание RRSHA3 Series
Страница 30: ...29 circuit ...
Страница 35: ...34 RRSHA Series Hot Air Blower User Manual ENM 3600 00 6 Schematics ...
Страница 36: ...35 ENM 3600 00 RRSHA Series Hot Air Blower User Manual ...
Страница 37: ...36 RRSHA Series Hot Air Blower User Manual ENM 3600 00 ...
Страница 38: ...37 ENM 3600 00 RRSHA Series Hot Air Blower User Manual ...
Страница 39: ...38 RRSHA Series Hot Air Blower User Manual ENM 3600 00 ...
Страница 40: ...39 ENM 3600 00 RRSHA Series Hot Air Blower User Manual ...