5 DSP~LINK3
Interface
The Monaco board provides a DSP~LINK3 interface through a ribbon cable connector.
The interface supports up to 4 slave DSP~LINK3 devices. The ribbon cable can be up to
12 inches (30 cm) long.
The DSP~LINK3 interface is accessed from node A’s local bus only; it is not accessible
from any other node nor from the VME bus. Accesses to the DSP~LINK3 interface do
not require the Global Shared Bus. As a result, DSP~LINK3 accesses can happen
concurrently with Global Shared Bus access by other devices (such as the other
processors or the SCV64 chip).
If a DSP~LINK3 access is interleaved within global shared SRAM accesses, node A
acquires the Global Shared Bus, performs the SRAM access, releases the Global Shared
Bus, performs the DSP~LINK3 access, acquires the Global Shared Bus, and then
performs the next Global Shared Bus SRAM access using a control register.
5.1.
DSP~LINK3 Data Transfer Operating Modes
The Monaco board supports four data transfer operating modes.
•
Standard Access
•
Standard Fast Access
•
Address Strobe Control
•
Ready Control Access
The three “access” data transfer operating modes (Standard, Standard Fast and Ready
Control) of the DSP~LINK3 interface use three 64K address spaces accessed from node
A. Each of the three “access” modes is assigned its own 64K memory space. Address
Strobe Control cycles are multiplexed with the Standard Fast Access mode space.
The following table shows how the DSP~LINK3 data transfer operating modes are
supported.
Содержание Monaco Quad 'C6x VME64
Страница 10: ...Monaco Technical Reference Spectrum Signal Processing Table of Contents x Part Number 500 00191 Revision 2 00 ...
Страница 20: ...Monaco Technical Reference Spectrum Signal Processing Introduction 8 Part Number 500 00191 Revision 2 00 ...
Страница 34: ...Monaco Technical Reference Spectrum Signal Processing Global Shared Bus 22 Part Number 500 00191 Revision 2 00 ...
Страница 70: ...Monaco Technical Reference Spectrum Signal Processing Registers 58 Part Number 500 00191 Revision 2 00 ...
Страница 74: ...Monaco Technical Reference Spectrum Signal Processing Specifications 62 Part Number 500 00191 Revision 2 00 ...
Страница 86: ...Monaco Technical Reference Spectrum Signal Processing Connector Pinouts 74 Part Number 500 00191 Revision 2 00 ...