BB24V1U UPS is designed to provide a local power solution for cable 

telephony, wireless local loop (WLL) and fiber to the home (FTTH) 

broadband equipment.

IMPORTANT SAFETY WARNINGS 

This manual has important instructions on installing and operating this device.  
Before you attempt to unpack, install or operate this device, thoroughly read this manual.

CAUTION

 Even when the AC input power is disconnected, the battery can still energize hazardous live parts inside of it.

 To reduce the risk of fire or electric shock, install the battery in a temperature- and humidity-controlled indoor area, free from  

 

  conductive contaminants. To find the acceptable temperature and humidity ranges, please refer to the device specifications.

 To reduce the risk of electric shock, keep the cover on. There are no user-serviceable parts inside the unit, including the  

 

  battery. Please contact us or our dealer for service.

 When replacing batteries, the replacement should have the same rating: Listed/Certified Valve Regulated Lead Acid  

 

  Battery, 12V, max. 10Ah.

 Before replacing batteries, remove conductive jewelry, such as chains, watches and rings, and use tools with insulated  

 

  handles. High energy passed through conductive materials can cause severe burns.

 Don’t dispose of batteries in a fire. Batteries may explode if improperly disposed. Recycle batteries in accordance with  

 

  local regulations.

 Don’t open or mutilate batteries. Battery material is harmful to the skin and eyes. It may be toxic.

 The UPS battery capacity can vary depending on storage time and temperature.

 The UPS battery is charging when it’s connected to utility power. The battery is charging during its first 24 hours of    

 

  normal operation. Don’t expect full battery capacity during this initial charging period.

Содержание BB24V1U

Страница 1: ...BB24V1U Battery User Manual ...

Страница 2: ...on There are no user serviceable parts inside the unit including the battery Please contact us or our dealer for service When replacing batteries the replacement should have the same rating Listed Certified Valve Regulated Lead Acid Battery 12V max 10Ah Before replacing batteries remove conductive jewelry such as chains watches and rings and use tools with insulated handles High energy passed thro...

Страница 3: ...d DC power cable DC jack Wall Mount 1 LED indicator 2 Button 3 AC power cable connector 4 DC power cable connector 5 UART serial communications USC connector 6 Battery cover Number Description Mounting Surface Max 5 16 1 1 5 1 8 Max 3 16 STEP 1 Connect the AC cable to an electrical outlet STEP 3 Use the wall mount template and a screwdriver to position screws on a wall Hang BB24V1U on the screws S...

Страница 4: ...B24V1U STEP 3 A Remove the battery from the enclosure B Disconnect both battery cable connectors STEP 4 A Install a new battery by connecting the red wire to positive terminal and the black wire to the negative terminal B Insert the battery into BB24V1U STEP 5 A Replace the battery cover to resume normal operation B Tighten the screw into the enclosure Fail Mute BLUE RED RED BLUE Batteryreplacemen...

Страница 5: ...al Message Voltage Range 100Vac 240Vac Frequency Range 50 60Hz Output On Battery Output Voltage 12Vdc Continuous Power Capability 36W Efficiency Max Load 80 Battery Battery Type Numbers of Battery 12Vdc 10Ah x 1 Typical Recharge Time 24 Hours Replaceable Surge Protection and Filtering Lightning Surge Protection Management Battery Auto Charge Yes Physical Dimensions LxWxD 18 5cm x 8 5cm x 18 7cm We...

Страница 6: ...of the PRODUCT could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities Charter expressly disclaims any express or implied warranty of fitness for High Risk Activities Charter does not authorize use of any PRODUCT in any High Risk activities ANY SUCH USE IS IMP...

Отзывы: