5. Remove one of the batteries from the Weather Station.
6. Unplug the cable of the old sensor from the “Temp/RH”
port.
7. Unscrew the gland at the bottom of the WS housing and
pull the cable out of the enclosure.
8. Remove the old sensor cable from the station, noting
how it is routed from the housing to the radiation shield.
You may have to cut a zip-tie to release the cable.
9. Route the new sensor’s cable along the same path that
the old cable used. Insert it through the cable hole and
screw in the gland. Plug the cable into the “Temp/RH”
port. Use the zip-tie to neatly tie the cable to a radiation
shield mounting post (see the photo on the right below).
10. Insert the battery. While the LCD is displaying
“PLEASE WAIT”, an “s” will appear in the lower left of
the LCD to indicate the new sensor is present.