26
Measurement
Units
Percent volumetric water content
Resolution
0.1%
Accuracy
±3.0% volumetric water content
with electrical conductivity < 2 dS m
–
1
Range
0% to saturation (
Saturation is typically
around 50% volumetric water.
)
Power
4 AAA alkaline batteries
Approximately 12 month life
Logger Capacity
2320 readings without GPS, 1160 read-
ings with GPS/DGPS
Display
16 character, 2 line LCD
Weight
3 lbs. (1.4 kg)
Probe Head
Dimensions
3.1”
x
3”
x
1”
(7.8cm x 7.5cm x 2.5cm)
Rod Dimensions
Length :
0.5”
(1.3cm),
1.0”
(2.5cm),
1.5”
(3.8cm),
3”
(7.6cm),
4.7”
(12cm) or
7.9”
(20cm)
Diameter:
0.2”
(0.5cm)
Spacing:
1.3”
(3.3cm)
Specifications
The internal data logger and RS
-
232 port are compatible
with GPS/DGPS. The data logger
’
s LCD screen will
display the data in one of three modes (see MODE button
p. 8):
1.
Volumetric water content
-
in Standard or High Clay
mode
2.
Relative water content
-
up to 2 RWC modes can be
established
3.
Measurement period
-
in microseconds