0114813R2 Page 3 of 7

Figure 1B

The locker back panel has four 3/8” holes located 16” on-center 

to match most stud-wall applications.  Fasteners are not included.  

(Cords from 16-outlet power units will route through bottom panel.)

1.  Choose fasteners appropriate to the wall you will be anchoring to.

2. 

Determine the preferred wall location and height from floor.

3.  Measure and mark the (4) hole locations on the wall.  

Figure 1B

.  Be sure fasteners will 

be anchored securely to studs or other solid portion of the wall.

4. 

At the marked wall locations, drill holes appropriate to the chosen fastener type and size.

5.  Support the locker (this may take 2-3 people), align the mounting holes, install fasteners, 

and tighten to secure the locker to the wall.  

Figure 1C

.

Four 3/8” holes are provided on the bottom panel to anchor the locker 

to a worksurface for increased security.  Fasteners are not included.  

(Cords from 16-outlet power units will route through side panel).

1. 

Set the locker into its final position.  (If attaching to a table or worksurface, 

be sure it is stable and sturdy enough to fully support the unit.)

2.  Choose fasteners appropriate to the surface you will be attaching to.  The 

(4) mounting holes in the bottom panel are 3/8” dia.  

Figure 1A

.

3.  Mark the (4) hole locations through bottom panel.

4.  At the marked locations, drill holes in the worksurface appropriate to the 

chosen fastener type and size.

5.  Install fasteners and tighten securely.

A. Worksurface anchoring

B. Wall-mounting

Figure 1A

WARNING

It is the customers responsibility to use appropri-

ate and adequate wall fasteners when attaching 

the IT32 Tablet Locker to a wall.  Nominal weight 

of an empty IT32 is 76 lbs.  Total loaded weight 

will vary with quantity & types of tablets used.

(4) 3/8” holes 

on back panel

Figure 1C

fasteners by 

customer

3/8” holes for customer-

supplied fasteners

3/8” holes for 

customer-supplied 

fasteners

Assembly / Setup

IT32 tablet locker security

Содержание InTouch 32

Страница 1: ...ed within 15 days of receipt To report information regard ing missing parts or damage to purchase parts or accessories or if you have any questions please contact us Thank you for purchasing Spectrum...

Страница 2: ...electrical outlet by gripping the cord Do not unplug the power cord by pulling only on the cord Do not step on drive over drag or place objects on the power cord For added safety plug the cart into a...

Страница 3: ...Fasteners are not included Cords from 16 outlet power units will route through side panel 1 Set the locker into its final position If attaching to a table or worksurface be sure it is stable and stur...

Страница 4: ...he side panel Figure 2A 2 Be sure both 16 outlet power units are unplugged and switched off 3 Plug up to 32 tablet chargers into the power units Figure 2B 4 Route the charge cords through the upper lo...

Страница 5: ...to use the recommended cord management method shown in the wiring diagram below Figure 3A tablets 16 outlet power unit s w tablet chargers 1 Use the cord management wraps above each tablet storage sl...

Страница 6: ...nto wall outlets and switch on to begin charging Figure 4 Door stop adjustment If necessary the offset door stop can be rotated slightly to adjust the closed position of the doors and lock rods 1 To r...

Страница 7: ...OR WARRANTY IN TORT OR OTHERWISE EXCEED THE PURCHASE PRICE RECEIVED BY SPECTRUM FOR THE PRODUCT AT ISSUE AND RECALL ACTION EXPENSES SPECTRUM SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIE...

Отзывы: