Adagio
Your color Pool-light is an advanced underwater luminaire with high quality LEDs
Ultra thin LED lamp for Pool & Spa
OWNER’S MANUAL
ColorCool whiteWarm whiteBlue
Страница 1: ...Adagio Your ADAGIO color Pool light is an advanced underwater luminaire with high quality LEDs Ultra thin LED lamp for Pool Spa OWNER S MANUAL Color Cool white Warm white Blue ...
Страница 2: ...tions setup 1 Wiring instructions setup 2 Retrofit with PAR56 niche only PLA170 14 Color programs Synchronizing color changing Classic ON OFF control Synchronizing color changing Intelligent PLC control Troubleshooting Page 3 Page 4 Page 5 Page 6 7 Page 8 9 Page 10 Page 11 Page 12 Page 13 Page 14 ...
Страница 3: ...5W 30W 60W Nominal CCT n a n a 5650K 5650K 2700K 2700K n a n a Electrical specifications Environmental specifications For operation only with a safety isolation transformer Minimum input voltage 9 VAC 50 60 Hz at lamp terminals Nominal input voltage 12 VAC 50 60 Hz at lamp terminals Maximum input voltage 13 VAC 50 60 Hz at lamp terminals Power factor 0 96 Maximum water temperature 35 C Lamps have ...
Страница 4: ...Box contents 1 1 2 3 5 100mm models 170mm models page 5 4 only for 170mm models page 4 of 16 ...
Страница 5: ...s not polarized Any of the two wires in the supplied cable can be connected to any terminal of the lamp PZA WTM PZA WC PZA100 XX XX PZA170 XX XX Warning The back side of the lamp and the driver tube have to be exposed to free flowing water during operation Fixing the lamps with ad hesives or silicone kit into a niche is not allowed and will void the warranty page 5 of 16 ...
Страница 6: ...p package Separate cable not included Toroïdal transformer is preferred because of better efficiency Wiring instructions Setup 1 Each lamp is connected to the transformer by a separate cable Preferred for new installations page 5 page 6 of 16 ...
Страница 7: ...0m 87 PLA170 RGB 7m 12m 20m 30m 120 LAMP TYPE 1 5 mm2 2 5 mm2 4 0 mm2 6 0 mm2 VA Transformer 12VAC MAX CABLE LENGTH BY CABLE SECTION The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps These cable lenghts are calculated with worst case voltage drops in the electrical wiring page 7 of 16 ...
Страница 8: ...ll lamps are connected to the transformer via 1 cable Wiring instructions Setup 2 4m cable included in lamp package Separate cable not included Toroïdal transformer is preferred because of better efficiency page 8 of 16 ...
Страница 9: ...3 5m 10m 20m 30m 294 4 5m 10m 15m 25m 392 PLA170 WH LC PLA170 WW LC PLA170 BL 1 25m 40m 60m 110m 87 2 12m 20m 30m 50m 174 3 7 5m 15m 20m 35m 261 4 5m 10m 15m 25m 348 1 12m 20m 30m 65m 120 2 7 5m 12 5m 20m 35m 240 3 5m 10m 15m 25m 360 4 7 5m 10m 15m 480 The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps These cable lenghts are calculated with worst ca...
Страница 10: ...cable is used OR Retrofit with PAR56 niche only PLA170 RETROFIT WITH PAR56 NICHE ONLY PLA170 5 Silicone tube If old cable is re used If new thinner cable is used OR 1 2 3 RETROFIT WITH PAR56 NICHE ONLY PLA170 5 Silicone tube If old cable is re used If new thinner cable is used OR page 10 of 16 ...
Страница 11: ...e Mid blue Light blue slowly changing VOODOO Red Wine red Purple Bordeau slowly changing DISCO Lila pink peach light yellow light green light blue quickly changing PARTY Blue azure blue green green red red red blue lila light pink peach yellow light green light blue lila slowly changing PROGRAM 12 to 14 3 white tones SUN WHITE Cool white NEUTRAL WHITE Neutral white WARM WHITE Warm white 1 2 3 4 5 ...
Страница 12: ...the 12 VAC line voltage and switch OFF 6 Switch ON the 12 VAC line voltage 7 The lamps should all be on the Deep Blue Sea program 1 showing fixed blue light Manual synchronization procedure After synchronization all lamps will run the same color program of choice To make synchronization possible all lamps should be connected to the same power line 12 VAC Changing colors PL REM P PL REM 60 PL REM 2...
Страница 13: ...d All the color programs and white tones are dimmable When the PLA REM or PLA REM 300 are connected to an external interface e g DMX controller each lamp can be controlled individually Synchronizing color changing For more detailed information about changing colors or individual pool light control see manual PLA REM 300 Option 2 Intelligent PLC control page 13 of 16 ...
Страница 14: ...synchronization as explained on p 12 only for classic ON OFF control 1 Switch the lamps ON For RGB lamps select the Sun White color program 2 Measure the voltage at the lamp terminals A Check the output voltage at the transformator terminals This voltage should be between 12VAC and 13VAC Verify that the used transformator VA rating is sufficient for powering all connected lamps B If the transforma...
Страница 15: ...Merchtem Belgium page 15 of 16 ...
Страница 16: ...on Systems bvba Dooren 72 1785 Merchtem Belgium Tel 32 2 461 02 53 Fax 32 2 706 59 60 www propulsionsystems be info propulsionsystems be page 16 We reserve the rights to change all or part of the contents of this document without prior notice ...