Wiring instructions Setup 1
12VAC
230VAC
Max cable length
4m cable attached to lamp
Separate cable (not included)
Toroïdal transformer is preferred because of better efficiency
Each lamp is connected to the transformer by a separate cable (Preferred for new installations)
LAMP TYPE
1,5 mm
2
2,5 mm
2
4,0 mm
2
6,0 mm
2
VA
TRANSFORMER
(12VAC) *
MAX CABLE LENGTH BY CABLE SECTION
* The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps.
These cable lenghts are calculated with worst case voltage drops in the electrical wiring.
PLS300(B)
PLS400(B)
PLS700(B)
PLW300(B)
PLW400(B)
PLW700(B)
70m
70m
60m
90m
60m
50m
120m
120m
100m
150m
100m
85m
180m
180m
160m
200m
160m
140m
200m
200m
200m
200m
200m
200m
16
22
25
18
26
30