SpectraPure
SpectraPure®Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
®
4
- SYSTEM SPECIFICATIONS -
Sediment Pre-Filter
0.5 micron MicroTec™ sediment pre-filter
Carbon Media
Granulated Activated Carbon
RO Membrane Type
Thin-Film Composite (TFC)
Rejection Rate
Greater than 98% average
Input Water Pressure
60 psi (4.15 bar) line pressure*
Input Water Temp
77°F (25°C)
Recovery Rate
20% (i.e. 20% of the water will be
collected
as
pure
water)
Nominal Membrane Flow Rates @ 60 psi & 77° F :
GPD
Product Water Flow Rate
Concentrate Flow Rate
600
25
gal/hr 264
ml/min
1400
105
gal/hr
420
ml/min
Reverse Osmosis Feed Water Requirements
For the 1 year TFC membrane pro-rated warranty to be honored, the following conditions
must be met:
Operating Pressure*
40 – 80 psi (2.75 – 5.5 bar)
pH
Range 3
–
11
Maximum Temperature
100° F (38° C)
Maximum
Turbidity 1.0
NTU
Maximum Silt Density Index
5.0 (based on 15 min. test time)
Maximum Chlorine
less than 0.1 ppm
Maximum
TDS 2000
ppm
Maximum Hardness
10 grains (170 ppm as CaCO3)
Maximum
Iron less
than
0.1
ppm
Maximum Manganese
less than 0.1 ppm
Maximum Hydrogen Sulfide
0 ppm
Langlier Saturation Index
LSI must be negative
*Operating pressure less than 40 psi will require a booster pump.
*Operating pressure greater than 80 psi will require a pressure reducing valve.
SpectraPure®Inc
. assumes no responsibility for water damages
due to leaks. It is the user’s responsibility to determine that the
system is leak-free by monitoring installation for 72 hrs.