9
STEP 10. CONNECT BULKHEAD FITTINGS:
Bulkhead Fittings MUST be installed on the same container that the floats are on, SEE
DIAGRAM ON PAGE 7.
3/8" BULKHEAD FITTING: Use a paddle bit and carefully drill a 13/16" hole for installation
at the top of the reservoir (above the high level float).
1/2" BULKHEAD FITTING: Use a paddle bit and carefully drill a hole for installlation at a
point below the high float.
STEP 11. FINAL CONNECTION:
Direct the waste line (yellow) to a drain.
NOTE: Look for leaks and do not leave the system unattended until you are sure
there are no leaks. Monitor the system for 72 hours.
CHECKLIST BEFORE LEAVING SYSTEM UNATTENDED:
• Ensure that all fittings are tight and leak-free before leaving the system unattended.
• The concentrate line (yellow) includes a smaller capillary tube (flow restrictor) that is
located “inside” the tubing. Do not remove or discard this restrictor. The system will
not produce permeate water without the flow restrictor.
• The following conditions must be met before water will flow throught the system:
The system must be powered up, the water source must be turned “ON” and the
water level in the reservoir tank must be below the low level float.