INSTALLATION
1. Replace your original DI cartridge with the new MaxCap
®
D1 cartridge.
2. Cut the tubing leading to the MaxCap
®
DI cartridge and insert the“IN” tee of
the TDS meter.
3. Cut the Tubing leaving the MaxCap
®
DI cartridge and insert the “OUT” tee of
the TDS meter.
4. Line up the dots on both probes and position the tees with the probes
hanging down.
5. Mount the meter body with velcro provided. The meter may be positioned
anywhere convenient for viewing.
6. Locate the tubing after the “OUT” tee, (which is after your original D1 housing
now containing the MaxCap
®
) and turn the feed water on. Rinse the MaxCap
®
DI into a bucket or down the drain until the “OUT” TDS reading is zero.
IMPORTANT: During the initial rinse up of the MaxCap
®
DI cartridge, a large
ionic load is presented to the downstream DI cartridges.
Be
sure to rinse up the new MaxCap
®
DI cartridge with the
downstream cartridge removed.
This rinsing step will ensure
that the MaxCap
®
DI cartridge is initially rinsed up to produce
high quality water before connecting your downstream
cartridge. Failure to rinse this upstream MaxCap
®
DI cartridge
may reduce the lifetime of your downstream DI cartridge.
7. Connect the tubing leaving the “OUT” tee to the input of the new DI housing.
(Mounting bracket provided)
8. Install your original DI cartridge into the new housing and rinse it up into the
bucket prior to connecting to your application.
TYPICAL 4-STAGE RO/DI SYSTEM