06-19-2018
UltraPrecise Auto Top Off
Liquid Level Controller
(LLC-UPLC-ATO)
INSTALLATION MANUAL
Страница 1: ...06 19 2018 UltraPrecise Auto Top Off Liquid Level Controller LLC UPLC ATO INSTALLATION MANUAL ...
Страница 2: ...OR LLC UPLC ATO IF ANY OF THE ITEMS LISTED BELOW ARE MISSING PLEASE CONTACT SPECTRAPURE PRIOR TO INSTALLATION Module w Sensor Tubes Attached 12 White Tubing Magnetic Sensor Holder Assembly Blue Warranty Card 12v 800mA Power Supply Operations Manual Allen Wrench TABLE OF CONTENTS System Features 3 System Specifications 3 Pump Connections and Controls 4 Setup Diagrams 5 Introduction 6 Familiarizing ...
Страница 3: ...de High reliability metal pump housing Virtually maintenance free No damage to the pump if run dry No check valves to clog or seals to leak Self priming and anti siphoning High limit Sensor Tube for fail safe operation High delivery pressure over 40 psi Compact size and cool operation Kalkwasser safe Quiet operation and low power consumption Complete system consumes less than 3 watts when pump is ...
Страница 4: ...h the hole in the end of the pump head See Servicing The Pump Module on Page 12 if the rollers don t move Power Connection Air Line Tubing to High Limit Sensor Tube Air Line Tubing to Primary Sensor Tube PUMP CONNECTIONS AND CONTROLS Pump Speed LED Indicator Lights also indicate seconds pump runs when in Duty Cycle mode Down Drain Pump Head Inspection Hole Up Fill INPUT from reservoir OUTPUT to aq...
Страница 5: ...he high limit sensor will shut the pump off if the water level reaches the top of the bevel in the tube Position the high limit sensor tube so any abnormal rise in the sump will deactivate the circuit and kill power to the ATO control module See page 10 for instructions in setting the high and low water levels The Sensor Tube should be mounted in the display tank or sump where the water level chan...
Страница 6: ...mp itself or 300 feet horizontally This is very handy if your sump is located on a different floor or in a different room than your aquarium or if you can t mount the pump in close proximity The ATO comes complete with a liquid level Sensor Tube which allows the user to set the levels of operation for the pump In Fill mode it turns on when the lower level is reached and turns off when the upper le...
Страница 7: ...t that time the pump will turn off and stay off until the level drops below the lower limit point again If the water level EVER reaches the high limit sensor tube the pump will be stopped and all six lights will blink rapidly in unison until the water level is lowered When power is normally applied the ATO will quickly go into its main mode of normal operation During normal operation the lights in...
Страница 8: ...r Tube in the water at the point on the tube where you want to set the lower limit This will be the level where the pump will turn on We recommend that you set this so that it is at least one inch from the open end of the tube 4 Press the DOWN button to set the lower limit 5 The three upper lights 6 8 and 10 will now blink in an upward sequence 6 Position the Primary Sensor Tube in the water at th...
Страница 9: ... All six lights will turn on briefly to indicate success These settings are remembered even after power is removed from the unit DUTY CYCLE SETUP 1 Power down the ATO unit 2 Press and hold the UP button 3 Power up the ATO unit 4 All six lights will flash twice to indicate that you are in Duty Cycle Mode then one or two lights will blink rapidly indicating the current setting for Duty Cycle Mode Se...
Страница 10: ...ring normal operation the lights will indicate the speed of the pump You may use the UP and DOWN buttons to adjust the speed of the pump When two adjacent lights are lit it indicates that the step is the number between these two e g If the lights next to 6 and 4 are both lit the pump is running at Step 5 NOTE The High Limit Sensor Tube acts as a safety backup It is on a separate circuit that will ...
Страница 11: ...our If the Duty Cycle is set to 1 2 seconds the overall rate will be about 18 ml min LEGEND Blinking Off Duty Cycle Duration Times These values represent the number of seconds the pump will run during a 20 second duty cycle The number values are doubled since this is based on a 20 second duty cycle When two adjacent lights are lit it represents the value between the two numbers NOTE The Duty Cycle...
Страница 12: ...e instructions apply to ALL SpectraPure Pump Products It is recommended that the pump head be inspected and cleaned or the tubing replaced per the following procedure Refer to images on pages 14 15 1 If you are just inspecting the pump head it is not absolutely necessary to disconnect the two tubings from the head but it might make this task easier Fig B 1 2 Use the provided 3 32 Allen Hex Key to ...
Страница 13: ...he pump body and the plastic wear strip is positioned to the inside so the rollers will contact the wear strip evenly Fig B 6 7 Place two of the three rollers into the pump body pushing them against the tubing Fig B 7 Hold them in position with your left thumb and then push the third roller into place Fig B 8 8 Carefully line up the locator pin with the slot in the inlet port Fig B 9 9 Press the p...
Страница 14: ...SpectraPure Inc 480 894 5437 Call us toll free 1 800 685 2783 2167 East Fifth St Tempe Arizona 85281 14 SpectraPure Fig B 1 Fig B 2 Fig B 3 Fig B 4 Fig B 5 Fig B 6 SERVICING THE PUMP MODULE continued ...
Страница 15: ...ctraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 sales spectrapure com www spectrapure com 15 SpectraPure Fig B 7 Fig B 8 Fig B 9 Fig B 10 Fig B 11 Fig B 12 SERVICING THE PUMP MODULE continued ...
Страница 16: ...eck for a loose connection on the suction side which will cause the pump to lose its prime FIVE YEAR LIMITED WARRANTY SpectraPure Inc warrants each new Ultra Precise ATO to the original owner only to be free of defects in material and workmanship for a period of 5 years from the date of receipt SpectraPure s liability under this warranty shall be limited to repairing or replacing on SpectraPure s ...