SYSTEM SPECIFICATIONS:
Carbon Prefilter
5 micron carbon block prefilter
RO Membrane Type
Thin-Film Composite (TFC)
Rejection Rate
Greater than 94%; 98% typical
Input Water Pressure
60 psi (4.15 bar) line pressure*
Input Water Temp
77°F (25°C)
Recovery Rate
33% (i.e. 33% of the water will be collected as pure water)
Nominal Membrane Flow Rates @ 60 psi, 77° F, & 500 ppm TDS :
GPD Product Water Flow Rate
Concentrate Flow Rate
100
263 ml/min
657 ml/min
200
526 ml/min
1315 ml/min
Reverse Osmosis Feed Water Requirements:
Operating Pressure*
40 – 80 psi (2.75 – 5.5 bar)
pH Range
3 – 11
Maximum Temperature
113° F (45° C)
Maximum Turbidity
1.0 NTU
Maximum Silt Density Index
5.0 (based on 15 min. test time)
Maximum Chlorine
less than 0.1 ppm
Maximum TDS
1500 ppm
Maximum Hardness
16 grains (272 ppm as CaCO
3
)
Maximum Iron
less than 0.1 ppm
Maximum Manganese
less than 0.1 ppm
Maximum Hydrogen Sulfide
0 ppm
Langelier Saturation Index
LSI must be negative
*Operating pressure less than 40 psi may require a booster pump: