Sediment Pre-Filter
0.5 micron MicroTec™ sediment pre-filter
Carbon Filter
0.5 micron carbon block pre-filter
RO Membrane Type
Thin-Film Composite (TFC)
Rejection Rate
Greater than 96% average
Input Water Pressure
60 psi (4.15 bar) line pressure*
Input Water Temp
77°F (25°C)
Recovery Rate
20% (i.e. 20% of the water will be
collected
as
pure
water)
Nominal Membrane Flow Rates @ 60 psi & 77° F :
GPD (lpd)
Product Water Flow Rate
Concentrate Flow Rate
25 (95)
66 ml/min
264 ml/min
40
(151)
105ml/min
420
ml/min
60 (228)
158 ml/min
632 ml/min
90
(340)
235ml/min
940
ml/min
180 (680)
470ml/min
1880 ml/min
Reverse Osmosis Feed Water Requirements
For the 1 year TFC membrane pro-rated warranty to be honored, the following conditions
must be met:
Operating Pressure*
40 – 80 psi (2.75 – 5.5 bar)
pH
Range 3
–
11
Maximum Temperature
100° F (38° C)
Maximum
Turbidity 1.0
NTU
Maximum Silt Density Index
5.0 (based on 15 min. test time)
Maximum Chlorine
less than 0.1 ppm
Maximum
TDS 2000
ppm
Maximum Hardness
10 grains (170 ppm as CaCO3)
Maximum
Iron less
than
0.1
ppm
Maximum Manganese
less than 0.1 ppm
Maximum Hydrogen Sulfide
0 ppm
Langlier Saturation Index
LSI must be negative
*Operating pressure less than 40 psi will require a booster pump:
less than 49 GPD use BPLF-MO-115(-230),
more than 49 GPD use BPHF-MO-115(-230).
*Operating pressure greater than 80 psi will require a pressure reducing valve.
SYSTEM SPECIFICATIONS: