SETUP PROCEDURES (continued)
STEP 9: CONNECT BULKHEAD FITTINGS:
(Bulkhead Fittings MUST be installed on the same container that the floats are on, SEE DIAGRAM ON PAGE 7)
STEP 10: FINAL CONNECTION:
A. Direct the waste line (yellow) to a drain or connect it permanently to a drain pipe via a Drain Saddle. (Drain
Saddle is not included with system.)
CAUTION:
Inspect for leaks and do not leave the system alone until you are sure there are no leaks.
Monitor the system for 72 hrs.
1/4" BULK HEAD FITTING:
Use a paddle bit and carefully drill a 5/8"
hole for installation at the top of the
reservoir (above the high level float).
3/8" BULK HEAD FITTING:
Use a paddle bit and carefully drill a 13/16"
hole for installation at the bottom of the
reservoir (below the low level float).
CAUTION
An extremely long drain line may create a siphon which will pull the water past the 4# check valve
and cause water to drain from the tank after shutdown. The following solution assumes that you
have already installed the system above the tank.
Route the yellow 1/4” waste water line up above the system as high as possible. Run a 1/2" drain pipe
(or a garden hose) from the drain location up vertically to the elevated yellow 1/4" waste water line.
Insert the waste water line down into the 1/2" drain line a few inches to create a “siphon break”.