SpectraLink Corporation
Installation and Operation
Link WTS – Link 150 M3 MCU
11.2 Change Companding
The factory setting on the
Link 150 MCU
is compatible with Mu-law companding
(signal compression), which is the standard used by most PBXs in North America.
Systems outside North America generally use A-law companding. If the PBX
companding is incompatible with the MCU's, the Wireless Telephones will have distorted
or hissing dial tone and voice will be unintelligible.
•
Before you begin, if the system has more than one MCU, erase the configurations
from all MCUs except MCU 1. Refer to 8.5
Replace an MCU
for instructions.
To change the default from Mu- to A-law on the
Link 150 MCU
follow these steps.
1. Power the system OFF.
2. Slide the mode switch on the first MCU to the
ADMIN
position.
3. Power the system ON. Status LEDs 2, 3, and 4 will be solid green.
4. Press the
STEP
button once. Status LEDs 2, and 5 will be lit.
5. If the LED for
LINE 1
is lit, the system is set for Mu-law.
If the LED for
LINE 2
is lit, the system is set for A-law.
6. Press the
DEL/ENTER
button to toggle between Mu-law and A-law.
7. When the correct
LINE
LED is lit, return the mode switch to the
NORM
position.
Part Number: 72007501D.doc
Page 49