SPECIFICATIONS (CONT.)
RADIO INTERFACE
• RF output 20 to 24 dBm at antenna connection
•
Sensitivity: typical -90 dBm measured at antenna
connection at BER = 0.001
•
Typical range:
– Indoor: 66 - 164 ft. (20 - 50 m.)
– Outdoor: 984 ft. (300 m.)
• Possible to connect external antenna
ELECTRO MAGNETIC COMPATIBILITY (EMS) APPROVALS
(REGULATORY STANDARDS)
•
EN 301 489-1
•
EN 301 489-6
• FCC RULES, FCC PART15
•
ANSI C63.4
SAFETY (REGULATORY STANDARDS)
•
UL60950-1
– CAN/CSA-C22.2 No. 60950-1
– AS/NZS 60950-1
•
EN 60950-1
DECT APPROVAL
•
EN 301 406
ENVIRONMENTAL CONDITIONS
• Operating temperature: 50º - 104º F (10º - 40º C)
• Storage temperature: -58º - 158º F (-50º - 70º C)
• Relative humidity: between 20% and 80% (non-condensing)
• The equipment is in compliance with the requirements of
EU directive 2002/95/EC (ROHS) and 2002/96/EC (WEEE)
ELECTRICAL REQUIREMENTS
•
Power over Ethernet (IEEE 802.3af), mode A & B
•
PoE Class 1 device
•
Typical power consumption: 3W per unit
• External power outlet (power supply must be ordered
separately)
PHYSICAL CHARACTERISTICS
• Size: 3.9 x 3.9 x 1.5 in. (100 x 100 x 38 mm)
•
Weight: 4.2 oz (120 gr.)
•
Grey-white (NCS 0502-Y)
•
Wall-mountable, indoor
•
The server can be mounted upside down
INTEROPERABILITY
• For information about supported PBX platforms, visit