Other LEDs:
LED green AC:
•
ON when AC power is monitored and present
•
OFF when AC power is not monitored
•
OFF when AC power is monitored and not present (in this case, “Non Urgent alarm is
active)
LED green DC:
•
ON when DC power is monitored and present,
•
OFF when DC power is not monitored
•
OFF when DC power is monitored and not present (in this case, “Non
urgent alarm is active)
LED green Eth:
ON when the SAS-E is connected with a network
LED red “Alarm nurg”:
ON when a non urgent alarm is generated
LED red “Alarm urg”:
ON when a urgent alarm is generated
3.5
3.5
3.5
3.5
Alarm
Alarm
Alarm
Alarm
The “Non Urgent alarm” is generated when:
o
Only one channel is detected fail in the case of both channel are monitored and the
SAS-E is not forced on the faulty channel. The output signals are still nominal.
o
Both channel are monitored and there are fail.
o
A default on a supervised power (AC or DC)
The “Urgent alarm” is generated when:
o
The SAS-E is forced on a channel and this one is detected as failed
o
Both channels are monitored and are detected as failed
o
At least one output is detected as failed
On each alarm connector and in case of an active alarm:
o
The contact relay between Pin 1 and Pin 2 is closed
Содержание SAS17E
Страница 4: ......
Страница 5: ...Spectracom Corporation EPSILON Switch Amplifier System E User s Manual iii ...
Страница 7: ...Spectracom Corporation EPSILON Switch Amplifier System E User s Manual v ...
Страница 8: ......
Страница 14: ...EPSILON Switch Amplifier System E Spectracom Corporation User s Manual 1 6 ...
Страница 16: ...EPSILON Switch Amplifier System E Spectracom Corporation User s Manual 1 8 1 7 2 SAS36E ...
Страница 22: ...EPSILON Switch Amplifier System E Spectracom Corporation User s Manual 2 6 ...