Fig. B: Flow Restrictor Tables

(For 4:1 Concentrate to Product Ratio)

FR-90

ml./min.

gpd

in.

cm.

269

102

1

2.5

233

88

2

5.1

213

81

3

7.6

198

75

4

10.2

183

69

5

12.7

175

67

6

15.2

164

62

7

17.8

154

58

8

20.3

148

56

9

22.9

141

54

10

25.4

136

52

11

27.9

133

50

12

30.5

129

49

13

33.0

128

48

14

35.6

124

47

15

38.1

124

47

16

40.6

PRODUCT RATE

CUT TO LENGTH

FR-180

ml./min.

gpd

in.

cm.

490

186

1

2.5

460

175

2

5.1

430

163

3

7.6

400

152

4

10.2

379

144

5

12.7

356

135

6

15.2

344

131

7

17.8

326

124

8

20.3

311

118

9

22.9

300

114

10

25.4

289

110

11

27.9

281

107

12

30.5

270

103

13

33.0

263

100

14

35.6

259

98

15

38.1

256

97

16

40.6

PRODUCT RATE

CUT TO LENGTH

(GREEN)

(YELLOW or WHITE)

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

15

SpectraPure

®

RO MEMBRANE DIAGNOSTICS

Although RO membranes are capable of maintaining high water quality 
over extended periods of time they eventually will begin to deteriorate. 
Normally, the conductivity of the permeate water will increase as the 
membranes age. By comparing the difference in TDS readings between 
the Tap water conductivity and the RO water conductivity, the per-
centage of rejection of the RO membrane may be calculated and the 
resultant number may then be used to determine the condition of the 
membrane and thus the operator will know when the membrane needs 
to be replaced. Membrane failure will be indicated by a reduction of the 
percentage of rejection which will be determined by calculating the dif-
ferential between the input and output numbers.  

In order to accurately determine the condition of the RO Membrane, a

conductivity tester (TDS meter) capable of reading the tap water 
conductivity and the permeate water conductivity has been provided 
with this system. With the assistance of the TDS meter you will be able to 
easily determine the RO membrane’s condition. (see page 7)
Before performing the diagnostic test on the RO membrane, make sure 
that the RO system has been “ON” and producing pure water for a mini-
mum of 10 minutes. Also check the brine (yellow) line to make sure that 
water is flowing and that the flow ratio between the permeate water 
and the brine water is at a ratio that is > 4 to 1. ( See Page 9). (NOTE: The 
pressure gauge should indicate a pressure reading of > 40 PSI during this 
15-20 minute test period. 
Procedure:
1.  Turn on the meter 1 by depressing the on switch.
2.  Locate the meter slide switch on the front of the DM-1 TDS meter. 
3.  Slide the switch to the “Left” and read the Tap water conductivity then 
     record the reading ________ .
4.  Next, slide the switch the to “Right” and read the permeate water 
     conductivity then record the reading ________.
5.  See page 7 on “TESTING THE RO MEMBRANE REJECTION RATE ” 

Содержание THE MAXCAP RO/DI System

Страница 1: ...ilter Wrench Optional Accessories Model Optional Part FAU SMP Quick Connect Faucet Coupler TK CL 10 Total Chlorine Test Kit VA FVK 4 Flush Valve Kit BPLF MO 115 Low Flow Booster Pump 115V BPLF MO 230...

Страница 2: ...for any consequential damages arising from installation or use of the product including any water or mold damage due to flooding which may occur due to malfunction or faulty installation including bu...

Страница 3: ...ered purchaser After repair or replacement the factory will return the unit or part freight prepaid to the customer 2 We assume no warranty liability in connection with our equipment other than as her...

Страница 4: ...sure greater than 80 psi will require a pressure reducing valve SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com...

Страница 5: ...water is passed through a 0 5 micron Micro Tec sediment pre filter This filter is required to remove excess turbidity particulate matter that may cause the carbon block filter to plug 2 The second st...

Страница 6: ...ure When the prefilters are new the pressure shown on the gauge will be slightly less than the actual tap water pressure and as the filters age the pressure will drop due to the dirt that will collect...

Страница 7: ...vi Acidify feed water to the RO membrane to improve its rejection h Faulty monitor probe Test and Replace if required SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra s...

Страница 8: ...at is located inside of the tubing Do not remove or discard this restrictor the system will not produce permeate water without the flow restrictor All of the following conditions must be met before wa...

Страница 9: ...assure you of maximum life and reliability of your SpectraPure System Failure to perform this procedure can permanently damage the membrane and will void the pro rated Membrane Warranty In order to m...

Страница 10: ...RO membrane may be calculated and the resultant number may then be used to determine the condition of the membrane and thus the operator will know when the membrane needs to be replaced Membrane failu...

Страница 11: ...te the yellow concentrate tubing Fig C Remove the tubing from its push fitting at the membrane as follows a Firmly depress and hold the push fitting collar down with your thumbnail b While the push fi...

Страница 12: ...fe the sediment pre filter must be changed when a 15 20 drop in pressure is observed OR at least 6 month intervals If your water contains a great deal of sediment the pre filter may require more frequ...

Отзывы: