background image

 

Spectra Watermakers, Inc. 

20 Mariposa Road, San Rafael, CA 94901 

Phone 415-526-2780   Fax 415-526-2787 

E-mail: [email protected] 

www.spectrawatermakers.com 

O9/22/05 Rotoflow 

 

Содержание Newport 1000

Страница 1: ...1 Spectra Watermakers Inc 20 Mariposa Road San Rafael CA 94901 Phone 415 526 2780 Fax 415 526 2787 E mail spectra spectrawatermakers com www spectrawatermakers com O9 22 05 Rotoflow...

Страница 2: ...2...

Страница 3: ...lete system before assuming the system is opera tional If the boat is in fresh or dirty water see Dry testing the system Spectra dealers are responsible for educating the vessel owners on the operatio...

Страница 4: ...4...

Страница 5: ...location 47 Z Brane Installation 59 Page Number New Systems Start Up and Testing 28 Dry Testing 31 Normal Start Up Using the Auto Run 33 Automatic Fresh Water Flush Cycle 34 Manual Operation 35 Mainte...

Страница 6: ...6...

Страница 7: ...will assist you in understanding the function of each component Layout the system Before starting the installation identify the location where each module and component will be placed Insure that the...

Страница 8: ...8...

Страница 9: ...ine as possible to avoid contamination and air induction The brine discharge through hull should be mounted above the waterline in or just above the boot stripe to minimize water lift Double clamp all...

Страница 10: ...tains a 50 Micron prefilter charcoal filter for the flush water flush solenoid and three way intake service valve Optional Z Brane The optional Z Brane Water treatment system is permanently in stalled...

Страница 11: ...4 1 2M from the pump module A long screwdriver will be required to access the fasteners The MPC Control Box Filters may be relocated for bet ter access or to prevent splashing water on sensitive equip...

Страница 12: ...5M reach of the wires from main feed pump module This unit may be placed as high in the boat as you desire Make sure that the area around and under the pump does not have any water sensitive equipmen...

Страница 13: ...wide by 2 7 8 68mm high opening for the panel Locate it in an area that is easily visible and easy to manipulate the buttons Use only Spectra approved remote cable Do not connect power to the alarm bu...

Страница 14: ...the overboard thru hull use the supplied 5 8 15 9mm clear braided vinyl hose 700 1000 System Tubing Schematic Note 700 1000 systems use Spectra high pres sure tubing with stainless fittings See Spect...

Страница 15: ...nlet thru hull to the flush module and from flush module to the pump module inlet use the supplied clear 3 4 19mm spiral suction rated hose The outlet of the filter assembly on the main module to the...

Страница 16: ...els See the Parker tube fitting assembly diagram next page Product water is pre plumbed from the membrane into the electric diversion valve The diversion valve will reject product water into the overb...

Страница 17: ...r 1 4 3 8 tube 1 2 tube should not bottom out in the fitting to allow full compression of the O ring Hand tighten the nut DO NOT OVER TIGHTEN DO NOT USE A WRENCH The tube should not come out if pulled...

Страница 18: ...ight while moving the tube around to prevent binding One thread should be showing under the nut Secure the tube so it won t back out when tightening Refer to figure 3 Use 13 16 wrench to hold a straig...

Страница 19: ...ation motor speed control and the MPC 3000 control board On the motor speed control are two potentiometers used to set the run flush and service speeds The speed control has over temperature shutdown...

Страница 20: ...n with al most any AC frequency Regardless of the input conditions the drive will hold a constant motor speed The motor controller output is three phase AC to the motor The control will soft starts th...

Страница 21: ...t splices These are heat shrink connectors so you can seal them after splicing Route the single two conductor cable to the fresh water flush module and splice the wires to the solenoid wires Heat the...

Страница 22: ...Wire length for a pair of wires is measured from source circuit breaker or fuse to control terminal block Wire Run Length Wire Run meters AWG wire size Sq mm wire size Less than 15 Less than 5 10 6 20...

Страница 23: ...0 awg 5 sq mm 50 feet to 75 feet 15M to 23M 8 awg 8 sq mm Wire length for a pair of wires is measured from source circuit breaker to control box Wire Length AWG wire size Square MM wire size To 25 fee...

Страница 24: ...erts in the event of a fault or at the end of certain timed cycles Use only the buzzer units supplied by Spectra Watermakers as current on the LCD buzzer terminal is limited to 20 mA any excessive loa...

Страница 25: ...seal the splice in waterproof heat shrink tubing Diversion Valve Salinity Probe Rotoflow Assembly This assembly is located at the Clark pump Membrane module on Newport models The sa linity probe shou...

Страница 26: ...at the bottom outlet at the top The ballast wires plug into the end of the bulb in the lamp module The ballast RED wire connects to STER terminal on the MPC board and the bal last BLACK wire connects...

Страница 27: ...rt up within five days it will automatically do a fresh water flush AutoFill mode can be ended by pushing the stop button or the Autoflush button If the watermaker is in Autorun mode it can be put int...

Страница 28: ...mbrane If the location or weather prevents proper testing refer to the section Dry Testing 1 First Check That Thru hull valve is open Power is on If you have an AC system both the AC power and the DC...

Страница 29: ...start 5 After the purge sequence The control will alarm with the message Close pressure relief valve C C C Cl l l lo o o os s s se e e e t t t th h h he e e e v v v va a a al l l lv v v ve e e e and...

Страница 30: ...lower with warm water or low salinity Filter Condition Service Prefilter alarm warns that filters are getting dirty Clean filters as soon as convenient A second Service Prefilters alarm means the filt...

Страница 31: ...ation Cycle the auto store system 5 more times to purge all of the storage chemicals out of the system 5 Hook up your service hoses per the service diagram and photos Route them into a 5 gallon 20 Lit...

Страница 32: ...e drawn in to make up the dif ference At initial startup the fresh water flush system should be tested by taking a sample of the brine discharge water just as the flush cycle is ending This water shou...

Страница 33: ...ncy Auto Run the system as long as possible each time The more product water you make each time the lower the proportion of product consumed by the flush cycle Never let the system sit with salt water...

Страница 34: ...closed if the system was just used to make water The auto flush may not operate if the valve is open The power for the system must remain on during the auto flush mode Turning off the power will disa...

Страница 35: ...water manifold outlet Bypass the diversion valve as follows Disconnect the 3 8 inch tube A that runs from the product manifold to the salin ity probe at the product manifold Product water will run out...

Страница 36: ...ystem is to be left unused for more than 2 weeks perform the following storage pro cedure The procedure introduces a chemical compound into the system that prevents bio logical growth This procedure r...

Страница 37: ...ule Lead the hose into the bucket Turn the service valve on the fresh water flush module 180 so the intake is now coming from the bucket Step 5 Mix the storage chemical compound into the water in the...

Страница 38: ...38 Push the Auto Flush button press Stop press Auto Flush again...

Страница 39: ...f the fresh water flush module Lead the hose into the bucket Turn the service valve on the fresh water flush module 180 so the intake is now coming from the bucket Step 5 Pump as much as possible of t...

Страница 40: ...ppears on the filter condition bar graph on the LCD display To service the filters shut off the thru hull open the housings discard the old filters Clean out the housing bowls reassemble the housings...

Страница 41: ...roughout the system will heat as it circulates in and out of the pot An alternative is to heat the one or two gallons of initial water to 120 on the main stove before mixing in the cleaner and circula...

Страница 42: ...Open unpressurized Step 7 Set the switches on the pump module to Service System and Flush Auto to turn on the feed pump Circulate the chemical in the system for approxi mately 25 minutes Allow to soak...

Страница 43: ...n the calibrate position where it can then be seen on the LCD display rather than a bar graph After adding the jumper it may be necessary to cycle through the different LCD displays until the display...

Страница 44: ...lamp until the pump head can be removed The suction and inlet hoses will come out with it Remove the green bonding wire from the stud on the pump body Loosen the hose clamp at the up per end of the su...

Страница 45: ...on the old pump using five wraps of Teflon tape The stainless steel fitting has to go in first Be careful not to cross thread the nylon hose elbow Install the suction hose and clamps and the discharg...

Страница 46: ...replacement strainer screen O ring for strainer screen O rings for filter housing Spectra Watermakers parts list SC 2 ORGANIC CONTAMINATION CLEANER FT CHE SC2 SC 3 MINERAL SCALE CLEANER FT CHE SC3 BAS...

Страница 47: ...ubes to one of the components secure the tube runs and then trim and connect to the other component A 90 degree bend in a tube is better than a 90 degree fitting A tube when mounted should have at lea...

Страница 48: ...tivates but pump will not run loose or broken pump wire connection bad pump relay tanks are full Check wiring at terminal block inside MPC Test power relay replace Replace fuse mini automo tive type A...

Страница 49: ...battery voltage too high or low loose wires or poor connec tions Charge batteries Check charging voltage Check power connections Re starting no signal from stroke sensor at startup System Air locked...

Страница 50: ...heduled fresh water flushes or by pickling Keeping the prefilters clean is also important in preventing bio fouling If your prefilters are allowed to become a breeding ground for bacteria get smelly t...

Страница 51: ...per minute Fill a bucket with fresh water and mix in a couple squirts of the detergent Run the system depressurized with the watermaker drawing water from the bucket and discharging over board When ab...

Страница 52: ...ne glycol based automotive antifreeze which is toxic Propylene glycol can be used instead of Spectra SC 1 storage chemical for storage in any climate up to one year following this procedure 1 Replace...

Страница 53: ...r only an hour or so a day will probably need to have the filters changed due to odor before they are dirty enough to restrict water flow Prefilters can be cleaned We recommend that you have three set...

Страница 54: ...n other models to avoid exceeding this flow rate If the ship s water system is unable to provide flush water at the required flow rate sea water will be drawn in to make up the difference This will ca...

Страница 55: ...f so equipped Plugged filters can be cleaned several times by soaking in a bucket towing behind the boat at moderate speeds or hosing them off When operated only an hour or two a day in inland or near...

Страница 56: ...g The membrane can only handle small amounts of chlorine for short periods without damage The chlorine will damage the bonding agent in the membrane in a very short time So if you skimp on the char co...

Страница 57: ...change a speed setting run the watermaker in the mode in which you want to change the speed For example If you want to change the speed the pump runs at while making water have the unit actually makin...

Страница 58: ...ble SETTING FLUSH SPEED Flush speed should be set to run the pump slowly enough that the vessels fresh water system can supply sufficient flow of water through the charcoal filter so that no sea water...

Страница 59: ...59 Z BRANE OPERATION MANUAL...

Страница 60: ...continuous 12Vor 24V DC power to be operative The installation of the Z Brane only consists of wiring the power supply to a continuous source The Z brane power supply can tolerate voltages between 10V...

Страница 61: ...e not only to protect the membrane but to prevent corrosion in the feed water system To achieve full effectiveness thoroughly fresh water flush the watermaker several times before leaving the vessel T...

Страница 62: ...P DT FM NPC FC FRONT COVER N P CHASSIS FM NPC ACB NEWPORT AC BOX FM NPC ACC NEWPORT AC BOX COVER For more information on the AC Tech drives please go to the technical section of our web site and downl...

Страница 63: ...VANE PUMP 240 250 AUST PL MTE 1 2X1 2S 1 2 X 1 2 TUBE FITT ELL SS PL PMP VBC V BAND CLAMP FOR ROTARY VANE PUMP PL PMP PCA MOTOR COUPLING AND ADAPTOR EL MTR 3 4AC220 3 4 HP 240 VAC 3 PHASE 56C MOTOR E...

Страница 64: ...ND CAP A FT PV ER MEMBRANE RING FM PVB PBE PLATE BRACKET END FM PVB PBI PLATE BRACKET INTERMEDIATE FM PVB PB PLATE BRACKET FT PV ER MEMBRANE RING PL NLT 1 2HP 1 2 HIGH PRESSURE TUBE DAYCO FT PV UTC U...

Страница 65: ...ERSION VALVE 12V W O VB PL SLN 1 4D24VB 1 4 DIVERSION VALVE 24V W O VB SUB NP DVM DIVERSION VALVE MANI FOLD EL SSR IFM INLINE ROTO FLOW METER PL MTS 1 4X1 4P 1 4 NPTX1 4 TUBE FITT ST PL MTE 3 8X3 8P 3...

Страница 66: ...4 50 MICRON FILTER ELEMENT FT FTC 50 3 4 MPT X 3 4 HOSE BARB ELBOW PL HBE 3 4X3 4 3 4 MPT X 3 8 TUBE FITT ELL PL MTE 3 4X3 8P 3 8 LOW PRESS TUBE PL NLT 3 8LP 1 4 MPT X 3 8 TUBE FITTING ELBOW PL MTE 1...

Страница 67: ...cylinder and base End block A End cap Cylinder ring Stainless steel tube End block B Valve block Alternate brine out Reset button Not on all units Test port Center block High pressure out Back View Hi...

Страница 68: ...acer ring Valve spool Spool piston End block A Piston O ring Valve bore O ring Spacer ring Valve block Brine port O ring Pilot port O rings Valve bore O ring 5 16 2 3 4 SS A H bolts Spool piston End b...

Страница 69: ...rings Pilot spool O rings 4 Mount inside block Pilot valve pin Pilot spool Pin seal O rings Center block Check valve retainer Check valve poppet Feed in Check valve washer Check valve spring Check val...

Страница 70: ...sembly End cap O ring Cylinder end cap Cylinder Ring S S compression fittings 1 2 SS tube Piston with seal Composite cylinder and base PL MTS 3 8X1 2S HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CY...

Отзывы: