11
Warning!
Your watermaker shipped from the factory with a non-toxic potable water system
preservative.
Damage may occur if this preservative is not flushed out and the membrane is
pressurized with preservative in it.
DO NOT OPERATE
the Aquifer system if the feed water could contain oil.
1. First:
You will need at least 50 gallons (200 liters) of salt, brackish, or fresh water.
If the water
has been chlorinated
or chemically treated,
replace the 5 micron filter with a Spectra
Watermakers Charcoal Filter element
during the flush.
Install the feed , brine, and product Hoses. Place the strainer end of the Feed Water Hose
into the feed water source far enough below the surface to prevent air from being pulled
in. Place the end of the brine hose so that the brine does not mix directly back in with the
feed water.
Install the product hose and place the end of it so that any product will be discarded
Ensure that the pressure relief valve is open 1/2 turn.
Plug in the AC power cord, connect solar panel, or ensure that the battery is fully charged.
2. Turn on the feed water pump. Check that it is primed by inspecting the brine discharge.
About 1.5 gpm (6 lpm) of water should be being discharged with a pulsation every few sec-
onds.
3. Run the system without pressure for 20 minutes to purge the storage chemicals. The sys-
tem should have an open flow pressure on the gauge of about 20 PSI (1.2 bar). Water may
drip from the product tube.
4. Close the pressure relief valve. The pressure should rise to 60-80 PSI (4.2-5.7 bar) if the
feed water is sea water. If the feed water is brackish or fresh the pressure will be lower.
After several minutes, water should begin to flow out of the product water tube.
5. Allow the system to run for 5-10 minutes to purge the product water of preservative, and
then test the product with your handheld salinity tester. When the product is below 750
PPM it is considered potable and may be diverted to the water container for human con-
sumption.
Aquifer New System Start-Up and Testing
Open 1/2 Turn to Purge Preservative!