background image

Spectra 64K Library Stability Kit Installation Procedure

2

Notices

Spectra Logic Corporation provides the unit “as is” without warranty of any kind, either 
expressed or implied, including but not limited to the implied warranties of merchantability or 
fitness for a particular purpose. In no event shall Spectra Logic be liable for any loss of profits, 
loss of business, loss of use or data, interruption of business, or for indirect, special, incidental, 
or consequential damages of any kind, even if Spectra Logic has been advised of the possibility of 
such damages arising from any defect or error.

Information furnished in this manual is believed to be accurate and reliable. However, no responsibility 
is assumed by Spectra Logic for its use. Due to continuing research and development, Spectra Logic may 
revise this publication from time to time without notice, and reserves the right to change any product 
specification at any time without notice.

Spectra 64K Library Stability Kit Installation Procedure
Copyright © 2004 Spectra Logic Corporation. All rights reserved.

Spectra Logic Contact Information

 

 

Corporate Headquarters

European Office

Address

Phone

Fax

Spectra Logic Corporation 
1700 N 55th Street 
Boulder CO 80301
USA 

(800) 833-1132 or (303) 449-6400

(303) 939-8844

Address

Phone

Fax

Spectra Logic Europe Limited
Magdalen Centre
Robert Robinson Avenue
Oxford Science Park
Oxford
UK OX44 7 RW

+44 (0) 870 112 2150

+44 (0) 870 112 2175

Web Site

http://www.SpectraLogic.com

Содержание Spectra 64K

Страница 1: ...P N 90910926 Revision A Spectra 64K Library Stability Kit Installation Procedure ...

Страница 2: ...l is believed to be accurate and reliable However no responsibility is assumed by Spectra Logic for its use Due to continuing research and development Spectra Logic may revise this publication from time to time without notice and reserves the right to change any product specification at any time without notice Spectra 64K Library Stability Kit Installation Procedure Copyright 2004 Spectra Logic Co...

Страница 3: ...Spectra 64K Library Stability Kit Installation Procedure 3 Contents Introduction 4 Before You Begin 5 Prepare the Library 6 Lower the Leveler Feet 8 Attach Brackets 9 Remove the Side Panels 10 Finish 12 ...

Страница 4: ...e fixed to a data center floor Estimated Time Required This procedure takes about 30 minutes Materials and Tools Required You need a Stability Kit from Spectra Logic P N 90911009 which includes Four L shaped brackets Eight 1 4 20 X 5 8 screws A 3 Phillips screwdriver Channel locks The library front door key A ladder will only be necessary if the side panels must be removed Figure 1 Thestabilitykit...

Страница 5: ...e You Begin 1 Disable any backup software that may try to access the library 2 Switch off the power button at the rear of the library 3 Disconnect the AC power cable 4 Disconnect all cabling Note You need access to all sides of the library to complete this procedure ...

Страница 6: ... of its rollers If you cannot access the leveler feet you must remove the side panels Proceed to Remove the Side Panels on page 10 Remove the Front and Rear Kick Plates 1 Both the front and rear kick plates snap in and out of place no tools are required to remove them Locate the front kick plate and pull it off Figure 2 Figure2 Remove thefront kick plate ...

Страница 7: ...Spectra 64K Library Stability Kit Installation Procedure 7 2 Locate the rear kick plate and pull it off Figure 3 3 Set aside both kick plates for later replacement Figure 3 Remove the rear kick plate ...

Страница 8: ...ger mobile Ensure that the library is in the desired location before lowering the leveler feet 1 Lower the front leveler feet Figure 4 Note It may be necessary to remove the rubber portion of the leveler feet to adequately grip the bolt head Note The leveler feet must be lowered enough to raise the library off of its rollers The distance the levelers need to be lowered may vary depending on the le...

Страница 9: ...llips screwdriver and four of the screws provided to attach two brackets to the front of the library Figure 5 2 Use a 3 Phillips screwdriver and the remaining four screws provided to attach two brackets to the rear of the library 3 Proceed to Finish on page 12 Figure 5 Attachfrontbrackets ...

Страница 10: ...e the side panels if you cannot access the leveler feet Otherwise proceed to Finish on page 12 1 Remove the library hood by lifting upward on the front of the library No tools are required to remove the hood Figure 6 Note A ladder may be required to access the top of the library o Figure 6 Removethelibrary hood ...

Страница 11: ...s to the library chassis Figure 7 3 After the screws have been removed the side panels are still snapped into place Pull off each side panel and set it aside for later replacement 4 Return to Remove the Front and Rear Kick Plates on page 6 to complete the procedure Figure 7 Removefourscrews attaching the side panels tothelibrary chassis ...

Страница 12: ...ood snap it into place 3 Replace the front kick plate 4 Replace the rear kick plate 5 Connect cabling 6 Connect the AC power cable 7 Power up the library 8 Enable backup software If You Have Difficulty If you need assistance call Spectra Logic Technical Support at 800 227 4637 or 303 449 0160 Inform the Technical Support representative that you are adding a stability kit to a Spectra 64K library ...

Отзывы: